HomeMy WebLinkAbout2026.11.17 Work Session Packet
4141 Douglas Drive North • Crystal, Minnesota 55422-1696
Tel: (763) 531-1000 • Fax: (763) 531-1188 • www.crystalmn.gov
Posted: Nov. 13, 2026
City Council Work Session Agenda
Tuesday, Nov. 17, 2026 | 6:30 p.m.
Upper Community Room/Zoom
Pursuant to due call and notice given in the manner prescribed by Section 3.01 of the City
Charter, the Crystal City Council work session was held on Tuesday, Nov. 17, 2026, at _____
p.m. electronically via Zoom and in the upper community room at city hall, 4141 Douglas Dr. N.,
Crystal, Minnesota. If the agenda items are not completed in time for the regular city council
meeting at 7 p.m., the meeting will be continued and resumed immediately following the
Economic Development Authority meeting.
I. Attendance
Council members Staff
____ Onesirosan ____ Bell
____ Budziszewski ____ Tierney
____ Cummings ____ Therres
____ Deshler ____ Elholm
____ Eidbo ____ Hubbard
____ Kamish ____ Kunde
____ Kiser ____ Struve
____ Sutter
____ Serres
II. Agenda
The purpose of the work session is to discuss the following agenda items:
1) Community Development quarterly update.
2) Council liaison reports.*
3) Constituent issues update.*
4) City manager update.*
5) New business.*
6) Council comments and announcements.*
7) Unified Development Code amendments.
III. Adjournment
The work session adjourned at ______ p.m.
* Denotes no supporting information included in the packet
Auxiliary aids are available upon request to individuals with disabilities by calling the city clerk at
(763) 531-1145 at least 96 hours in advance. TTY users may call Minnesota Relay at 711 or 1-800-627-3529.
Community Development Dept.
3Q 2026 Update
November 17, 2026John Sutter
Community Development Director
(763) 531-1130
john.sutter@crystalmn.gov
www.crystalmn.gov
Who we are
(seven full-time employees)
Chandler Clay
Building & Housing Inspector
John Sutter
Director
Dan Olson
City Planner
Joe Tomasetti
Building Official
Jeni Taylor
Building & Commercial Inspector
Jason Zimmermann
Code Enforcement Manager
Ashton Amsler
Code Enforcement Inspector
What we do
•Plan reviews and inspections for permits
•Rental licensing and inspections (616 houses
and 2,097 apartments)
•Planning and zoning (Planning Commission)
•Code enforcement, both residential
neighborhoods and commercial property
•Business and development inquiries
•EDA activities and special projects
2026 3Q Highlights
Lotus Pointe (6000 56th) -Foundation
complete and framing underway
Ember (7000 56th) -Foundation and plan
review for phase 2 nearly complete
30% design of TIF-funded improvements
near 7000 56th
Ribbon cuttings at Five Guys and Inkakaw
Decorative downtown lighting installed
39 new commercial code enforcement
cases initiated
Planning Commission items:•CUP for Verizon tower at 3200 Vera Cruz•Proposed UDC amendments
Permits, Inspections
and Code Enforcement
Summary
Revenue Summary
2024 thru Sep. 30 2025 thru Sep. 30 2026 thru Sep. 30
DISCUSS UDC AMENDMENTS
PAGE 1 OF 8
____________________________________________________________________________________
FROM: Dan Olson, City Planner
TO: Adam R. Bell, City Manager (for November 17 meeting)
DATE: November 10, 2026
RE: Discuss proposed amendments to the Unified Development Code
____________________________________________________________________________________
A. BACKGROUND
Staff is requesting that City Council discuss proposed amendments to the unified development
code (UDC). The proposed amendments include policy changes on three issues, as well as
corrections or clarifications, brought about by things we learned while administering the UDC.
Attachments:
A. Proposed ordinance amendments
B. Areas C and D from 2040 Comprehensive Plan
C. Current zoning map showing areas for UO-PD
D. Building design requirements from other cities
B. PLANNING COMMISSION COMMENTS
At the October 12, 2026 Planning Commission meeting, the Commission provided comments on
the proposed UDC amendments. The following is a summary of those comments, followed by
staff response.
1. Policy changes. The Commission was supportive of the three proposed policy changes
described in section C of this staff report, to add the UO-PD overlay district, increase
densities in the R-1, R-2, and R-3 districts, and to include additional building design
requirements.
Staff response. Unless directed otherwise by City Council, staff will include exterior building
material requirements such as found in West St. Paul, Richfield, and St. Louis Park in the
proposed UDC amendments.
COUNCIL STAFF REPORT
Discuss UDC amendments
DISCUSS UDC AMENDMENTS
PAGE 2 OF 8
2. Clarifications and corrections. The Commission was supportive of those proposed
amendments described in section D of this staff report.
Staff response. These amendments will be included in the proposed ordinance for the
Commission’s public hearing.
3. Amendment requests from Commission member Sumnicht. Commission member Tony
Sumnicht submitted three suggested amendments for Planning Commission review relating
to the establishment of zoning requirements for data centers, plug-in solar panels, and
reducing parking for smaller commercial developments.
Staff response. Staff recommends the following for these proposed amendments.
a. Data centers. The UDC does not have a principal use called “data centers”, and therefore
that use would not be allowed (staff proposes to strengthen the UDC language with this
amendment that makes it clear that if a use is not listed it is not allowed). If City Council
desires to allow data centers, staff has added proposed amendment language for that
use in attachment A (pages 11, 79, 87-88, 129) which includes the following:
• A general definition in section 505.
• Data centers would be allowed in the Industrial (I) and Airport (AP) districts with
an approved conditional use permit (CUP). Smaller facilities would be allowed in
the I and AP districts, while larger facilities would only be allowed in the AP
district.
• Use-specific standards to address site development standards, including limits on
the size of the facility, noise, water and energy consumption.
b. Plug-in solar panels.
• Plug-in solar panels plug directly into a standard wall outlet and can be set on a
patio or in a yard (and occasionally on a roof), while conventional solar panels
are larger, permanently hardwired into the main electrical panel by professional
installers, and are typically installed to be flush mounted on a roof.
• Plug-in solar panels are far less expensive than conventional panels.
• Neither the UDC, state building code, or state statute have specific requirements
for plug-in panels. Staff is not aware of any municipalities that have specific
requirements for plug-in solar panels.
• Plug-ins that are not placed on a building, such as those set on a patio, would not
require approval of a building permit and therefore would not be subject to
zoning approval.
• Staff recommended UDC amendments:
➢ Clarify that plug-in panels, not mounted on a building, are not subject to
zoning requirements.
➢ Require building-mounted plug-in rooftop panels to either be flush
mounted or have a height limit when oriented at maximum tilt.
DISCUSS UDC AMENDMENTS
PAGE 3 OF 8
c. Reduce parking requirements for commercial development.
• The amendment proposes to eliminate minimum required number of parking
spaces for commercial development of 5,000 gross sq. ft. or less in the NC and C
districts.
• Staff recommended UDC amendments:
➢ Stand-alone commercial developments under 5,000 gross sq. ft. of
building space in the NC and C districts have no minimum required
number of parking spaces.
➢ Multi-tenant commercial developments in the NC and C in the NC and C
districts have no minimum required number of parking spaces for the
first 5,000 sq. ft. of total gross building floor area, but standard parking
requirements apply once that threshold has been met.
C. PROPOSED POLICY CHANGES
Staff has identified the following three issues involving a change of policy that will require
additional discussion.
1. Create new redevelopment overlay zoning district called Urban Option – Planned
Development district (UO-PD). The UO-PD overlay district would provide those properties
outside the town center area the opportunity to redevelop according to the urban
standards required in the Town Center (TC) and Town Center – Planned Development (TC-
PD) districts. The proposed UO-PD district roughly aligns to redevelopment areas C and D
in the Comprehensive Plan (attachment B), plus additional properties as described below
and shown in attachment C. The UO-PD district is an overlay district that property owners
could opt into to create urban style development. The Council should provide input on
whether the site development standards (such as building height, setbacks, and density,
should be different than the town center area (see current town center requirements
below).
Site plan element TC requirement UO-PD requirement (if different
from TC)
Building height 5 stories or 60’, whichever is less
Front setback Minimum: 1’
Maximum: 12’
Interior side
setback
None
Rear setback Minimum: 5’
Corner side
setback
Minimum: 2’
Maximum: 12’
Buildings to be built up to corner
Density TC: 25-80 units per acre
TC-PD: 16-64 units per acre
DISCUSS UDC AMENDMENTS
PAGE 4 OF 8
Principal uses TC: Primarily retail, personal
services, eating establishments
and multi-family residential
TC-PD: Also religious
institutions, schools, and
specialized care facilities
Minimum number
of parking spaces
TC nonresidential: None
TC residential: 1 space per unit
plus 1 space for each 10 units
for visitor parking
TC-PD: Standard number of
parking spaces based on specific
use, but applicant can request a
reduction during rezoning
process
Minimum lot area,
width and depth
None
Building street
frontage
Building should occupy 60-75%
of the lot width
Minimum green
space
90% of the lot can be impervious
surface
Properties proposed to be included in the UO-PD overlay district (attachment C):
6401 – 42nd Ave. N. Hennepin County library
4141 Douglas Dr. N. City hall, police station & fire station
4174 Douglas Dr. N. Single-family home
4168 Douglas Dr. N. Single-family home
4162 Douglas Dr. N. Single-family home
4156 Douglas Dr. N. Single-family home
4150 Douglas Dr. N. Single-family home
4142 Douglas Dr. N. Single-family home
4134 Douglas Dr. N. Single-family home
4100 Douglas Dr. N. (two lots) Ascension Church
4173 Colorado Ave. N. Single-family home
4167 Colorado Ave. N. Single-family home
4161 Colorado Ave. N. Single-family home
4149 Colorado Ave. N. Single-family home
4141 Colorado Ave. N. Single-family home
4131 Colorado Ave. N. Single-family home
4121 Brunswick Ave. N. City of Crystal reservoir
3915 Adair Ave. N. Robbinsdale School District office
(formerly FAIR school)
6125 – 41st Ave. N. City of Crystal public works
DISCUSS UDC AMENDMENTS
PAGE 5 OF 8
6225 – 42nd Ave N. Access Veterinary Care
6209 - 42nd Ave. N Inka Dental
6129 – 42nd Ave. N. Two barber shops
6113 - 6121 42nd Ave. N. Keng’s Chow Mein, Panaderia restaurant
6105 – 42nd Ave. N. Elision Playhouse
6023 – 42nd Ave. N. Tumble Fresh Coin Laundry
6001 – 42nd Ave. N. Adair Liquor
4169 Adair Ave. N. Single-family home
4171 Adair Ave. N Single-family home
6000 – 42nd Ave. N. Big B’s Gas & Goods
4217 Adair Ave. N. Single-family home
6016 – 42nd Ave. N. Tobacco shop
6028 – 42nd Ave. N. Retail businesses
4222 Brunswick Ave. N. Single-family home
6122 – 42nd Ave. N. Brunswick United Methodist Church
4210 – 4300 Douglas Dr. N. Almsted’s Fresh Market
4308 Douglas Dr. N. Single-family home
4320 Douglas Dr. N. Single-family home
4309 Colorado Ave. N. Two unit residential building
4321 Colorado Ave. N. Two unit residential building
6304 – 42nd Ave. N. B & R Transmission
5930 West Broadway Apartment buildings
5924 West Broadway Geneva Discount Furniture
5900 West Broadway Apartment buildings
3600 Douglas Dr. N. Wine Thief/Ale Jail
6203 – 36th Ave. N. Eight townhome units
3528-3550 Douglas Dr. N. Retail businesses with associated parking
lot
3504-3518 Douglas Dr. N. Eight townhome units
3448 Douglas Dr. N. Single-family home
3442 Douglas Dr. N. Single-family home
3430 Douglas Dr. N. Single-family home
3422 Douglas Dr. N. Single-family home
3414 Douglas Dr. N. Single-family home
3408 Douglas Dr. N. Single-family home
3400 Douglas Dr. N. Storage building
3354 Douglas Dr. N. Vacant EDA lot
6213 – 34th Ave. N. Vacant EDA lot
6203 – 34th Ave. N. Single-family home
3342 Douglas Dr. N. (two lots) Single-family home
3320 Douglas Dr. N. Apartment building
3300 Douglas Dr. N. Apartment building
3246 Douglas Dr. N. Apartment building
3212 Douglas Dr. N. Single-family home
3200 Douglas Dr. N. Two unit residential building
DISCUSS UDC AMENDMENTS
PAGE 6 OF 8
3201 -3255 Colorado Ave. N. Nine vacant residential lots on
unimproved street
6101 – 6215 32nd Ave. N. 18 townhome units
3141 Douglas Dr. N. Apartment building
3157 Douglas Dr. N. Apartment building
3201 Douglas Dr. N. El Chino Auto Sales
3219 Douglas Dr. N. Apartment building
3237 Douglas Dr. N. Three unit residential building
3255 Douglas Dr. N. Two unit residential building
3305 Douglas Dr. N. Single-family home
3317 Douglas Dr. N. Apartment building
3335 Douglas Dr. N. Apartment building
3353 Douglas Dr. N. Realtor office
6307 – 34th Ave. N. Single-family home
3401-3417 Douglas Dr. N. Eight townhome units
6308 – 34th Ave. N. Vacant office building
3400 Edgewood Ave. N. Single-family home
3412-3418 Edgewood Ave. N. Two vacant residential lots
3421-3437 Douglas Dr. N. Eight townhome units
3443 Douglas Dr. N. Vacant EDA lot
3501 Douglas Dr. N. Suite Living Senior Care
3517 Douglas Dr. N. Vacant commercial lot
3537 Douglas Dr. N. Retail businesses with associated parking
lot
6319 – 36th Ave. N. Single-family home
6327 – 36th Ave. N. Single-family home
2700 Douglas Dr. N. Lamplighter Square shopping center
6300- 6400 27th Ave. N. Sedona Hills apartments
2756 Douglas Dr. N. Office building
2701 Brunswick Ave. N. Apartment buildings
2900 Douglas Dr. N. Apartment building
2725 – 2761 Dougla Dr. N. Six townhome units
6600 – 27th Ave. N. Neill Elementary School
2801 Douglas Dr. N. LDS Church
4701 – 36th Ave. N. Thrift store
4725 – 36th Ave. N. Pinnacle Dermatology
2. Increase density in R-1, R-2 and R-3 districts (page 121). To promote opportunities for
more housing, the densities in the three base residential districts are proposed to increase.
3. Adopt additional building design requirements. City council has expressed an interest in
requiring additional exterior building requirements in the city’s redevelopment districts.
Attachment D provides exterior building requirements for the cities of West St. Paul,
Richfield, St. Louis Park, and Hopkins. These cities have a predominantly suburban
development pattern that is slowly transitioning to an urban development pattern.
DISCUSS UDC AMENDMENTS
PAGE 7 OF 8
However, Hopkins is unique in that it also has a substantial historic downtown and the
Planning Commission consensus is that its design guidelines are not a good fit for Crystal.
The Council is asked to provide a recommendation on whether additional design
requirements should be adopted.
D.CLARIFICATIONS AND CORRECTIONS
The majority of proposed UDC amendments would not be policy changes, but instead
clarifications and corrections to existing requirements. The following are the proposed
amendments:
1.Construction site office (pages 10, 108). The amendment adds a definition and
requirements for temporary offices for construction projects.
2.Signs.
➢(page 23). The city attorney recommends deleting the word “speech” since the
city’s sign code is content-neutral.
➢Page 99). Clarifies sign requirements for home businesses.
➢(page 182). Amendment clarifies that signs for home businesses and garage and
yard sales have different requirements than listed in this subsection related to
placement of signs in the right-of-way.
➢(pages 183, 186). Amendment prohibits illuminated signs, including
electronically or electrically controlled readerboards, that are near low density
residential areas to be lit between 10 p.m. and 6 a.m. A conflicting standard for
the NC district is deleted.
➢(pages 185, 186, 187). Amendment ensures that the same terminology is used
throughout the UDC for electronically or electrically controlled readerboards.
➢(page 187). Clarifies that frontage roads are defined as minor collector streets for
the purpose of calculating sign size.
➢(page 189). Allows more than one sandwich board sign for multiple-tenant
commercial buildings; clarifies in which zoning district wall signs are allowed.
➢(page 190). Since the state’s requirements for election signs can change, this
amendment references the state statute for these regulations.
3.Planning Commission (pages 29-30). Removes repetition of requirements already found
in chapter 3; replaces the environmental quality commission with the sustainability
commission.
4.Site plan amendments (page 39). Clarifies what defines an amendment and increases
the threshold at which the amendment can be approved administratively by city staff.
5.Renaming of two zoning district classification (examples on pages 47 and 49). While
approving the Town Center Vision Plan (TCVP), City Council discussed renaming the
Town Center Base (TC) district to Downtown District and the Town Center-Planned
Development (TC-PD) overlay district to Downtown Edge (DE) overlay district. These
changes are proposed through the UDC but shown as examples on pages 47 and 49.
6.Remove height limit in Town Center (TC) district (pages 54, 122). This amendment
proposes to remove the height limit for buildings in the TC district. To prevent negative
impacts on residential properties, a specific standard is proposed for shadow effects
(see item #13 below).
DISCUSS UDC AMENDMENTS
PAGE 8 OF 8
7.Unlisted uses (pages 77, 96-97, and 107). This amendment clarifies that if a principal,
accessory or temporary use is not listed in the use tables, then that use is not allowed.
An applicant may apply for a UDC text amendment to add the use.
8.Retail uses in the TC district (page 85). Establishes a process for requesting additional
square footage in the TC district and allows for a limited amount of storage space.
9.Locational requirements for auto-oriented uses (pages 85-86). Clarifies locational
requirements for vehicle sales and repair.
10.Firewood cribs (page 96). Clarifies requirements for firewood cribs.
11.Architectural requirements for commercial storage buildings (page 103). Establishes
exterior material requirements for this type of detached building that are the same
requirements for other detached buildings.
12.Noncommercial greenhouses (page 104, 126). Allows greenhouses on single and two-
family properties in the same locations as other detached buildings.
13.Outdoor dining (page 109). For clarification purposes, the amendment is to use the
same terms for outdoor dining used in other sections of the UDC.
14.Shadow effects (pages 115-116). Establishes a standard and requirements for principal
building shadows that may impact adjacent residential uses.
15.Side setback for attached decks (page 124). Increases the side setback for attached
decks from 3’ to 5’, so that the home and deck have the same requirement.
16.Height limits for NC district (page 128). This amendment provides a height limit for
accessory buildings in the NC district, similar to what is found in other districts.
17.Blank walls for airplane hangars (page 129). The amendment allows airplane hangars to
have blank walls.
18.Fence height for corner residential lots (pages 130-131). Provides a property owner
height options for fences in the front and corner side yard but ensures that fences in
front of the home’s entry will not exceed 4.5’ in height.
19.Current vehicle registration for single and two family dwellings (page 145). City council
members have expressed interest in restoring the requirement that vehicles parked
outside on single and two family properties have current registration (it is already
required on other types of properties).
20.Driveways (page 153, 155). This amendment provides specific standards for auxiliary
parking space tapers in the right-of-way and for water curb stops in driveways
(requested by the city engineer).
E.REQUESTED ACTION
City Council to discuss and provide comments on the proposed UDC amendments.
The following is the proposed schedule for considering the proposed UDC amendments:
January 11 Planning Commission public hearing
January 19 Council considers first reading of ordinance
February 2 Council considers second reading and adoption
February 11 Summary of ordinance published
March 13 Effective date of ordinance
10
CR225-464-620540.v15
Subd. 33. Cannabis Retailer Business. “Cannabis Retailer Business” means a cannabis business
that is a cannabis retailer, the retail portion of a cannabis mezzobusiness with a retail operations
endorsement, or the retail portion of a cannabis microbusiness with a retail operations endorsement, a
cannabis delivery service license, a cannabis business license with a delivery service endorsement, as those
terms are defined in Minnesota Statutes, section 342.01 and applicable Minnesota administrative rules.
Subd. 34. Canopy. “Canopy” means a roof-like cover, often made of fabric, plastic, metal, or glass
on a support, which is affixed to a building and provides shelter over a doorway.
Subd. 35. Carport. “Carport” means an accessory structure used generally for covering vehicles
which is open on at least two sides. It may be attached to the home or be freestanding. If the structure is not
open on at least two sides, it is considered a garage and shall comply with all requirements in this UDC for
garages.
Subd. 36. Cemeteries. “Cemeteries” means land used or dedicated to the burial of the dead,
including mausoleums, necessary-related sales, and maintenance facilities. A funeral home may be included
when operated within the boundary of such cemetery.
Subd. 37. City. “City” means the City of Crystal, unless otherwise noted.
Subd. 38. Club or lodge. “Club or lodge” means buildings or facilities owned or operated by a
corporation, association, or persons for a social, educational, or recreational purpose; but not those which
are primarily for profit or which render a service that is customarily carried on as a business.
Subd. 39. Commercial truck storage or parking. “Commercial truck storage or parking” means a
parking lot used for the storage or temporary parking of commercial vehicles in excess of three quarter (3/4)
ton capacity.
Subd. 40. Commercial storage building. “Commercial storage building” means a detached
accessory building that is over 200 square feet in size and used primarily for storage for a commercial
business. For the purposes of this UDC, commercial storage buildings are not synonymous with self-storage
facilities.
Subd. 41. Comprehensive plan. “Comprehensive plan” means the formally adopted comprehensive
development plan of the city, composed of maps, charts, diagrams, and text describing the recommended
policies and programs to guide the city’s future development and redevelopment.
Subd. ___. Construction site office. “Construction site office” means a temporary structure, such
as a travel trailer, used as an office in conjunction with an active construction project and for no other
purpose.
Subd. 42. Control measure. “Control measure” means a practice or combination of practices to
control erosion and attendant pollution.
Subd. 43. Critical facilities. “Critical facilities” means facilities necessary to a community’s public
health and safety, those that store or produce highly volatile, toxic or water-reactive materials, and those
that house occupants that may be insufficiently mobile to avoid loss of life or injury. Examples of critical
facilities include schools, daycare facilities, nursing homes, fire and police stations, wastewater treatment
facilities, public electric utilities, water plants, fuel storage facilities, and waste handling and storage
facilities.
Subd. 44. Curb cut. “Curb cut” has the meaning given it in the Crystal city code, chapter VIII.
Attachment A
11
CR225-464-620540.v15
Subd. ____. Data center. “Data center” means a facility whose primary function is to house
computers and/or equipment for the purpose of collection, processing, storage or retrieval of data.
Subd. 45 Day care facilities, Adult. “Day care facilities, Adult” means a facility providing care for
the elderly or functionally-impaired adults in a protective setting for a portion of the day. For day care
facilities for children, see “Day care facilities, in-home”, Day care, group family facilities” and “Schools,
nursery or preschool”.
Subd. 46. Day care facilities, in-home. “Day care facilities, in-home” means a day care facility
under rules and statutes of the State of Minnesota serving and providing care to 12 or fewer children.
Subd. 47 Day care, group family facilities. “Day care, group family facilities” means a facility
licensed under Minnesota Rules, parts 9502.0315 to 9502.0445 and which serves 14 or fewer children.
Subd. 48. Deck, detached. “Deck, detached” means a freestanding deck which does not utilize the
exterior wall of the principal structure for support.
Subd. 49. Detention facility. “Detention facility” means a permanent natural or man-made
structure, including wetlands, for the temporary storage of runoff which contains a permanent pool of
stormwater.
Subd. 50. Development. “Development” means any manmade change to improved or unimproved
real estate, including buildings or other structures, dredging, filling, grading, paving, excavation, or drilling
operations, or storage of equipment or materials.
Subd. 51. Driveway. “Driveway” has the meaning given it in the Crystal city code, chapter VIII.
Subd. 52. Driveway approach. “Driveway approach” has the meaning given it in the Crystal city
code, chapter VIII.
Subd. 53. Drive-through establishment. “Drive-through establishment” means any portion of a
building, structure or property from which business is transacted, or is capable of being transacted, directly
with customers located in a motor vehicle.
Subd. 54. Dry cleaning plant. “Dry cleaning plant” means a building, portion of a building, or
premises used for cleaning fabrics, textiles, or wearing apparel by immersion or agitation, or by immersions
only, in volatile solvents including solvents of the petroleum distillate type, and/or the chlorinated
hydrocarbon type, and the processes incidental thereto.
Subd. 55. Dwelling. “Dwelling” means a building or portion thereof used exclusively for residential
purposes, forming a habitable unit for one family. Garages, tents, and accessory structures shall not be
considered dwellings and shall at no time be used as a dwelling, either temporarily or permanently. Tents
may be used for recreational purposes.
Subd. 56. Dwelling, multiple family. “Dwelling, multiple family” means a building designed with
three or more dwellings exclusively for occupancy by three or more families living independently of each
other.
Subd. 57. Dwelling, one-family attached. “Dwelling, one-family attached” means a building, such
as townhouses or row houses, containing dwellings in which:
(a)Each dwelling is located on its own parcel;
(b)Each dwelling is attached to another by party walls without openings; and
23
CR225-464-620540.v15
(o) Nonconforming sign. “Nonconforming sign” means any sign and its support structure lawfully
erected prior to the effective date of this UDC which fails to conform to the requirements of
this UDC. A sign which was erected in accordance with a variance granted prior to the adoption
of this UDC and which does not comply with this UDC shall be deemed to be a legal
nonconforming sign. A sign which was unlawfully erected shall be deemed to be an illegal
sign.
(p) Off-premise sign. “Off-premise sign” means a commercial speech sign which directs the
attention of the public to a business, activity conducted, or product sold or offered at a location
not located on the same premises where such business sign is located. For the purposes of this
UDC:
(1) A freestanding, monument or pylon sign shared by adjacent property owners shall not be
considered an off-premise sign.
(2) Easements and other appurtenances shall be considered to be outside such platted parcel of
land and any sign located or proposed to be located in an easement or other appurtenance
shall be considered an off-premise sign.
(q) On-premise sign. “On-premise sign” means a sign that pertains to the use of the premises or
the property on which it is located.
(r) Pole sign. “Pole sign” means a sign which has the same meaning as pylon sign (see definition).
(s) Portable sign. “Portable sign” means any sign which is manifestly designed to be transported,
including by trailer or on its own wheels, even though the wheels of such sign may be removed
and the remaining chassis or support is converted to another sign or attached temporarily or
permanently to the ground since this characteristic is based on the design of such a sign.
(t) Projecting sign. “Projecting sign” means any sign which is affixed to a building or wall in such
a manner that its leading edge extends more than 15 inches beyond the surface of such building
or wall face. A projecting sign is also a sign located above or below a canopy or marquee.
(u) Pylon sign. “Pylon sign” means any freestanding sign which has its supportive structure(s)
anchored in the ground and which has a sign face elevated above ground level by pole(s) or
beam(s) and with the area below the sign face open.
(v) Roof sign. “Roof sign” means any sign erected and constructed wholly on and above the roof
of a building, supported by the roof structure, and extending vertically above the highest portion
of the roof.
(w) Rotating sign. “Rotating sign” means a sign or portion of a sign which turns about on an axis.
(x) Sandwich board sign. “Sandwich board sign” means a moveable sign not attached to the
ground and constructed in such as manner as for form an “A” or a tent-like shape, hinged or
not at the top, each angular face held at an approximate distance by a supporting member.
(y) Shimmering sign. “Shimmering sign” means a sign which reflects an oscillating sometimes
distorted visual image.
(z) Small sign. “Small sign” means a single sign six square feet or less in size.
29
CR225-464-620540.v15
Section 510
Administration
510.01. Applicability.
Subd. 1. Procedures. All land use and development permit applications, except building permits,
shall be governed by the procedures contained in this section.
Subd. 2. Procedural review processes. There are three different levels of procedural reviews for
applications submitted to the city. These three types of review procedures are described in the Crystal city
code, subsection 510.11. This UDC further identifies which procedural review shall be necessary based
upon each type of application. To the extent that any application process does not outline a procedural
review, the zoning administrator shall determine the appropriate level of review.
Subd. 3. Specific review processes. Specific procedures and decision criteria for each type of
development review application are contained in the Crystal city code, subsection 510.13.
Subd. 4. Appeals of administrative decisions. Appeals of any order, requirement, decision, or
determination made by an administrative officer in the enforcement of the UDC may be brought as provided
in the Crystal city code, subsection 510.35.
Subd. 5. Appeals of final decisions. The decisions of the city council under this UDC are final,
except that any person aggrieved by a final decision of the city council may appeal the decision to district
court as provided in Minnesota Statutes, section 462.361. In order to be timely, any such appeal shall be
filed with the district court within 30 days of the date of the decision.
510.03. Planning commission.
Subd. 1. Established. The planning commission is hereby established for the city. The planning
commission is designated as the planning agency of the city in accordance with Minnesota Statutes, section
462.354.
Subd. 2. Purpose. The purpose of the planning commission is to assist the city council in all matters
relating to zoning and development or redevelopment of properties within Crystal. The planning
commission’s role is advisory in nature.
Subd. 3. Duties. The planning commission has those powers and duties assigned to it by Minnesota
Statutes, sections 462.351 to 462.364, (the Municipal Planning Act) and as further provided under this
UDC.
Subd.4. Members. The planning commission shall be made up of nine members. There shall be at
least two planning commission members from each of the four city wards. The remaining planning
commission member shall be appointed on an at-large basis.
Subd. 5. Qualifications. Planning commission members must be residents of the city and be at least
fifteen years old. Qualifications for planning commission members are found in the Crystal city code,
subsection 305.13.
Subd. 6. Removal. Planning commission members serve at the pleasure of the city council and may
be removed from the commission, with or without cause, upon a majority vote of the city
council.Requirements for removal of planning commission members are found in the Crystal city code,
subsection 305.13.
30
CR225-464-620540.v15
Subd. 7. Terms. Planning commission members shall be appointed to three-year terms. There are
no term limits. To help ensure continuity in the planning commission’s work, the terms shall be staggered.
As such, terms for the first nine planning commission members prescribed by this UDC shall expire as
follows:
(a) Four terms shall expire on December 31, 2017.
(b) Three terms shall expire on December 31, 2018.
(c) Two terms shall expire on December 31, 2019.
Subd. 8. Other commissions. While serving on the planning commission, planning commission
members may not also concurrently serve on the city’s parks and recreation commission or environmental
quality sustainability commission.
Subd. 9. Compensation. Planning commission members shall serve without compensation, but may
be reimbursed for actual and necessary expenses if funds for that purpose are identified in the adopted city
budget.
Subd. 10. Liaison. The planning commission shall have both a city council liaison and a staff
liaison. The city council liaison shall be assigned by the mayor. The staff liaison shall be assigned by the
city manager. The commission may also have a staff secretary who is responsible for taking and preparing
minutes during planning commission meetings.
Subd. 11. Operations. The planning commission shall conduct itself in accordance with this UDC,
the Crystal city code, section 305, the planning commission’s bylaws, and all other applicable laws and
ordinances.
510.05. Board of appeals and adjustments.
Subd. 1. Board of appeals and adjustments. Pursuant to Minnesota Statutes, section 462.354, the
city of Crystal board of appeals and adjustments is hereby established for the city. The city’s planning
commission shall serve as the board of appeals and adjustments for the city. Pursuant to Minnesota Statutes,
section 462.354, subdivision 2, the decisions of the board of appeals and adjustments are advisory to the
city council, which will make all final decisions. The Board shall operate under the same requirements as
the planning commission in the Crystal city code, subsection 510.03.
Subd. 2. Duties of the board. The board of appeals and adjustments shall have the following duties:
(a) The board of appeals and adjustments hears and makes recommendations with respect to
appeals from any order, decision, or determination made by an administrative officer in the
enforcement of this UDC.
(b) The board of appeals and adjustments hears requests for variances from literal provisions of
this UDC in accordance with the provisions of Minnesota Statutes, section 462.357.
(c) The board of appeals and adjustments hears appeals from the denial of a building permit for
structures within the limits of a mapped street pursuant to Minnesota Statutes, section 462.359.
510.07. Zoning administrator.
Subd. 1. Appointment. The city manager shall appoint a zoning administrator to administer and
enforce this UDC.
39
CR225-464-620540.v15
(4) Replacement of a multiple family dwelling or nonresidential building on the same footprint
and with the same height with no other site changes requested.
(5) Airport facilities.
(b) Site plans for the following construction requires approval through a Type 2 review procedure
as established in this UDC:
(1) New multiple-family dwellings of three units or more;
(2) New nonresidential structures;
(3) Additions to multiple-family dwellings or nonresidential structures of greater than 50
percent of the building footprint;
(4) New parking ramps or structures.
(c) Approval criteria. No site plan review application shall be approved unless it meets the
following criteria:
(1) It fully complies with all applicable requirements of this UDC;
(2) It adequately protects residential uses from the potential adverse effects of a non-residential
use;
(3) It is consistent with the use and character of surrounding properties; and
(4) It provides safe conditions for pedestrians or motorists and prevents the dangerous
arrangement of pedestrian and vehicular ways.
(d) Amendments to approved site plans approved through a Type 2 procedure.
(1) After a site plan has been approved through a Type 2 procedure, the applicant may request
approval of adjustments or rearrangements of buildings in the course of carrying out the
plan. If the amendment involves increases or decreases changes to of 10 percent or less of
the original floor area, not to exceed 500 1,000 square feet, the zoning administrator may
approve the amendment after a Type 1 review procedure. Such amendment shall be in full
compliance with the requirements of this UDC. If the amendment involves changes
increases or decreases greater than 10 percent of the original floor area or exceeds 500
1,000 square feet, the amendment will be subject to a Type 2 review procedure.
(2) The zoning administrator may also review and approve adjustments or rearrangements of
items other than buildings, such as drives, parking areas, recreation areas, entrances,
heights, yards, signage, landscaping, exterior lighting, surface water management plans, or
similar modifications subject to a Type 1 review procedure. Such amendment shall be in
full compliance with the requirements of this UDC.
(e) Effect of city council decision of site plans approved through a Type 2 procedure.
(1) Site plan approval shall expire one year from the date of approval unless the applicant has
been issued a building permit for the work. Site plan approval shall also expire two years
from the date of approval unless the work is complete and the building permit is finaled
and closed.
47
CR225-464-620540.v15
(a) A request to rezone a property to Town CenterDowntown Edge Planned Development (TCDE-
PD) shall only be allowed for those properties identified on the official zoning map as located
within the TCDE-PD overlay district. When a property has been rezoned to TCDE-PD, there
shall be no underlying zoning district classification.
Subd. 2. Effect of city council decision.
(a) If a site plan has been approved as part of the rezoning, the approval of a rezoning to a PD
overlay district shall expire one year from the date of approval unless the applicant has been
issued a building permit for the work. Site plan approval shall also expire two years after the
date of approval unless the work is complete and the building permit is finaled and closed.
(b) The applicant may request an extension of the expiration date in writing to the zoning
administrator. The city council may approve one extension of not more than one year. Such
written request shall include the following:
(1) An explanation of what, if any, good faith efforts have been made to complete the site plan
process; and
(2) The anticipated completion date.
(c) If the rezoning to a PD expires and the applicant has not received approval of an extension, the
city council may rezone the property to the original zoning classification at the time of the PD
application or to a zoning classification consistent with the comprehensive plan designation for
the property.
(d) A rezoning to a PD overlay district may continue in operation, regardless of ownership or
ownership changes, provided the use meets all the standards and conditions of approval.
510.33. Variance.
Subd. 1. Applicability. A variance is a modification or variation of the provisions of this UDC as
applied to a specific piece of property. Pursuant to the procedures provided in Minnesota Statutes, section
462.357, use variances are prohibited.
Subd. 2. Approval procedure. Variance applications shall be submitted, in writing, to the zoning
administrator and are subject to a Type 2 review procedure.
Subd. 3. Approval criteria.
(a) Pursuant to Minnesota Statutes, section 462.357, subdivision 6, the board of adjustments and
appeals may only grant approval of variances where practical difficulties exist as to strict
compliance with this UDC and each of the following criteria are satisfied:
(1) The variance is in harmony with the general purposes and intent of this UDC;
(2) The variance is consistent with the Comprehensive Plan;
(3) The property owner proposes to use the property in a reasonable manner not permitted by
this UDC;
(4) The plight of the landowner is due to circumstances unique to the property not created by
the landowner; and
49
CR225-464-620540.v15
Section 515
Zoning Districts and Use Regulation
515.01. Official zoning map. The official zoning map together with all materials attached thereto is hereby
adopted by reference and declared to be a part of this section. The official zoning map shall be on file with
the city clerk.
515.03. Establishment of zoning districts.
(a) Established. The zoning classifications and zoning districts specified in Table 2 are hereby
established within the city to carry out the purposes of this UDC.
Table 2: Zoning Districts
Abbreviation District Name
BASE ZONING DISTRICTS
R1 Low Density Residential District
R2 Medium Density Residential District
R3 High Density Residential District
NC Neighborhood Commercial District
C Commercial District
TCD Town Center CoreDowntown District
I Industrial District
AP Airport District
OVERLAY ZONING DISTRICTS
FP Floodplain Overlay District
SL Shoreland Overlay District
PD Planned Development Overlay District
DE-PD Downtown Edge Planned Development Overlay District
UO-PD Urban Option Planned Development Overlay District
(b) Relationship of overlay districts to base districts.
(1) Where land is classified into an overlay zoning district, the regulations governing
development in the overlay district shall apply in addition to the regulations governing the
underlying base district, unless otherwise noted. In the event of a conflict between the
standards of the overlay district and the base district, the standards governing the overlay
district shall control.
(2) In some instances land may be classified into multiple overlay districts. In the event of a
conflict between the standards of the multiple overlay districts, the most restrictive
standards shall apply.
(c) Zoning district boundaries.
54
CR225-464-620540.v15
(2) Building height. Principal buildings do not have maximum height requirements but are
subject to the following height requirements, in addition to those requirements found in the
the Crystal city code subsection 520.01, subd. 5: Maximum building height requirements
are shown in Crystal city code, subsection 520.03.
(i) The following are additional height requirements.
(ai) Story height. Stories above the ground floor are limited to 12 feet in height. Stories
are measured from finished floor to finished ceiling.
(bii) Ground floor height. If the ground floor has a non-residential use, the ground
floor height shall be no less than 12 feet in height, but not more than 20 feet.
Ground floor height above 20 feet counts as an additional story.
(iii) Views. The building will not have significant negative impacts to the views of
Becker Park by neighboring properties.
(civ) Shadow effects study The applicant shall submit a shadow effects study to
determine any negative shadow impacts to residential uses within 300 percent of
the building height. If negative impacts are determined, the city may require design
techniques to mitigate the impacts, such as reducing the height of the building,
relocating or reorienting the building within the site, reducing building mass, or
stepping-back a portion of the building.
(dv) Proximity to Crystal Airport. Buildings shall comply with Crystal city code,
subsection 520.01, subdivision 5(c) for construction near the Crystal Airport.
(ii) Exceed height limitations. The city may, in its discretion, allow buildings to be
constructed to a height of eight stories or 100 feet, whichever is less, upon
consideration of the following factors.
(a) Shadow effects. Shadow effects from the taller building will not have significant
negative impacts on neighboring properties. A shadow effects study may be
required by the city to document these impacts.
(b) Building massing. The dimensions of the taller building are not disproportionately
larger than neighboring buildings.
(c) Views. The taller building will not have significant negative impacts to the views
of Becker Park by neighboring properties.
(3) Building facades. Building facades shall meet the following requirements.
(i) Building articulation. Buildings exceeding 50 feet in width along a street shall
incorporate articulation in street-facing facades to break down the scale of large
buildings and create visual interest. Techniques to incorporate articulation include
stepping back or extending forward a portion of the façade, using different textures or
contrasting but compatible materials, dividing the building into storefronts with
separate display windows and entrances, use of awnings, balconies, or similar
ornamental features, or varying the roofline to reinforce the articulation of the primary
façade (see Figure 8).
77
CR225-464-620540.v15
amount of activity, the type of customers or residents, how goods or services are sold or
delivered, and site conditions.
(2) Use types. The use categories are divided into specific use types. The use types identify
the specific uses that are considered to fall within characteristics identified in the broader
use category. For example, one-family or two-family are some of the specific use types
that fall under the “household living” use category.
(b) Symbols in table. The symbols used in Table 3 are defined as follows:
(1) Permitted uses (P). A “P” in a cell indicates that a use type is allowed by-right in the
respective zoning district subject to compliance with the use-specific standards set forth in
the final “use-specific standards” column of Table 3. Permitted uses are subject to all other
applicable standards of this UDC;
(2) Conditional uses (C). A “C” in a cell indicates that a use type is allowed as a conditional
use in the respective zoning district subject to compliance with the use-specific standards
set forth in the final “use-specific standards” column of Table 3 and approval of a
conditional use permit in accordance with the Crystal city code, subsection 510.19.
Conditional uses are subject to all other applicable standards of this UDC.
(3) Prohibited uses (--). A cell with a “--" indicates that the listed use type is prohibited in the
respective zoning district.
(4) Use-specific standards. The “use-specific standards” column of Table 3 cross-reference
standards that are specific to an individual use type and are applicable to that use in all
districts unless otherwise stated in the use-specific standards.
(5) Unlisted uses. If an application is submitted for a use that is not listed in Table 3, the use
is not permitted. The applicant may submit an application for an amendment to the text of
the UDC according to the requirements of the Crystal city code subsection 510.29. zoning
administrator is authorized to classify the new or unlisted use, with consultation from
appropriate city departments, into an existing use type that most closely fits the new or
unlisted use. If no similar use determination can be made, the zoning administrator shall
refer the use to the planning commission, who may initiate an amendment to the text of
this UDC to clarify where and how the use should be permitted.
Table 3: Permitted Principal Uses
Use Category and Use Type
P = Permitted Use
C = Conditional Use
- = Not Permitted
Base Zoning Districts
Use-Specific
Standards in
Section: R-1 R-2 R-3 NC C TC I AP Residential Use Category
Bed and Breakfast
Establishments
C C C C - - - - 515.19, subdivision 2
(a)
Dwellings, Multiple Family - P P _ - P - - 515.19, subdivision 2
(b)
79
CR225-464-620540.v15
Table 3: Permitted Principal Uses
Use Category and Use Type
P = Permitted Use
C = Conditional Use
- = Not Permitted
Base Zoning Districts
Use-Specific
Standards in
Section: R-1 R-2 R-3 NC C TC I AP Offices, Professional - P P P P P 515.19, subdivision 4
(g)
Off-Sale Liquor Store - - - - P P P - 1200 & 515.19,
subdivision (h)
Parking Ramps or
Structures
- - - - P P P P 515.19, subdivision 4
(i)
Personal Services - - - P P P P - 515.19, subdivision 4
(j)
Principal Cannabis
Business
- - - - - - C - 515.19, subdivision 4
(k)
Restaurants or Eating
Establishments
- - - P P P P -
Retail Establishments - - - P P P P - 515.19, subdivision 4
(l)
Theater, Indoor - - - C P P - -
Tobacco Shop - - _ P P P - 1105 & 515.19,
subdivision 4 (m)
Vehicle Repair - - - - C - P - 515.19, subdivision 4
(n)
Vehicle, Boat or
Recreational Sales or
Rental
- - - - P - P - 515.19, subdivision 4
(o)
Vehicle Fuel Sales - - - - P - - - 515.19, subdivision 4
(p)
Vehicle Wash or Detailing - - - - C - C - 515.19, subdivision 4
(q)
Industrial, Manufacturing, Research and Wholesale Use Category
Building Materials Sales - - - - - - P -
Bulk Storage of Liquids - - - - P - P P 515.19, subdivision 5
(a)
Cannabis or hemp
industrial business
- - - - _ - C - 515.19, subdivision 5
(b)
Data centers - - - - - - C C 515.19, subdivision 5
(c)
Industrial Uses (Indoors) - - - - - - P -
Industrial Or Commercial
Uses with Outdoor Storage
of Parts, Products, or Fuels
- - - - - - P - 515.19, subdivision 5
(cd)
Self Storage Facilities - - - - - - P -
85
CR225-464-620540.v15
county, then no cannabis retailer businesses are allowed in the city and the city shall not
undertake process in the Minnesota Statutes, section 342.22 to register any such business.
(l) Retail establishments. Retail establishments are subject to the following standards:
(1) Repair is allowed for a retail establishment, but a conditional use permit is required if the
repair is done outdoors. The applicant shall demonstrate that such outdoor repair will not
negatively impact neighboring properties;
(2) Within the TC district, retail space is limited to 15,000 gross square feet per floor, but .
Additional additional square footage may be allowed with an approved conditional use
permit., not to exceed a building footprint of 20,000 square feet No more than 5% of the
gross floor area can be used for a storage (warehouse) use;
(3) Within the NC and Commercial districts, retail establishments may have up to 50% of the
gross floor area as storage or warehouse space; and
(4) Within the Industrial district, retail establishments are limited to 50% of the gross floor
area of the principal use.
(5) Any retail establishment engaging in the sale at retail of any cannabis product, tobacco,
or liquor at off-sale shall not be located within 500 feet of a school, public park, or
residential treatment facility. The following apply for the purposes of this paragraph.
(i) The distance between properties shall be measured from the closest points between
the lot containing the business and the lot containing the identified use to which the
buffer applies.
(ii) The term “school” means a public or private facility that provides educational
programs to ten or more people who are under the age of 21 in a classroom setting.
The term includes, but is not limited to, any school operated by an independent school
district or a charter school operating under Minnesota Statutes, chapter 124E. The
term does not include the Robbinsdale Transition Center or similar adult education
schools.
(iii) The term “public park” means an open space, playground, athletic field, or other
facility owned by the city, a school district, the county, or other public entity that is
open to, and regularly used by, those under the age of 21.
(iv) The term “residential treatment facility” means a facility providing mental health,
alcohol, or drug treatment services established or operated in accordance with
Minnesota Rules 2960, or Minnesota Statutes, chapters 245G or 260C.
(m) Tobacco shops. Tobacco shops are subject to the following standards:
(1) Shall comply with the standards imposed on retail establishments under subdivision 4 (l)
of this subsection.
(2) Shall not be located in any buffer zoned identified in subdivision 4 (l) (5) of this subsection.
(n) Vehicle repair. Vehicle repair is subject to the following standards:
(1) The property abuts at least one of the following street segments West Broadway between
Corvallis Avenue North and the Canadian Pacific railroad;:
86
CR225-464-620540.v15
(i) West Broadway between Corvallis Avenue and the Canadian Pacific (CP) railroad;
or
(2) There is no outdoor parking or storage of vehicles that are to be worked on, are being
worked on, or have been worked on.
(o) Vehicle, boat, or recreational sales or rental. Vehicle, boat, or recreational sales or rental is
subject to the following standards:
(1) The property abuts at least one of the following street segments West Broadway between
Corvallis Avenue North and the Canadian Pacific railroad:;
(i) West Broadway between Corvallis Avenue and the Canadian Pacific (CP) railroad;
or
(2) There is no outdoor parking or storage of inoperable, unlicensed, abandoned or junk
vehicles; and
(3) No vehicle or equipment shall exceed 32 feet in length.
(p) Vehicle fuel sales. Vehicle fuel sales are subject to the following standards:
(1) The property abuts at least one of the following street segments:
(i) West Broadway between Corvallis Avenue and the Canadian Pacific (CP) railroad;
or
(ii) 36th Avenue North between Highway 100 and a point 357 feet west of the centerline
of Regent Avenue North.
(2) Sufficient vehicular stacking space is provided on-site to minimize the blocking of traffic
in the public right-of-way; and
(3) If the property is adjacent to one or two residential family dwellings, the vehicle fuel sales
businesses shall be closed between the hours of midnight and 5 a.m.
(q) Vehicle wash or detailing. Vehicle wash or detailing establishments are subject to the following
standards:
(1) The property abuts at least one of the following street segments:
(i) West Broadway between Corvallis Avenue and the Canadian Pacific (CP) railroad;
or
(ii) 36th Avenue North between Highway 100 and a point 357 feet west of the centerline
of Regent Avenue North;
(2) Sufficient vehicular stacking space is provided on-site to minimize the blocking of traffic
in the public right-of-way.
(3) A vehicle wash or detailing establishment shall comply with the use-specific standards for
drive-through facilities in the Crystal city code, subsection 515.23, Subd. 2 (b).
Subd. 5. Industrial, manufacturing, research and wholesale use category.
87
CR225-464-620540.v15
(a) Bulk storage of liquids. If the storage is within 300 feet of properties used for residential
purposes, such storage shall not exceed 25,000 gallons.
(b) Cannabis or hemp industrial businesses. Cannabis or hemp industrial businesses are subject to
the following standards:
(1) Businesses shall submit an odor mitigation plan that outlines all odor emitting aspects
of the business and mitigations to be implemented to ensure odor is not readily
detectable beyond the boundaries of the immediate site upon establishment of the
business and for the full duration of the business.
(2) Outdoor cultivation of cannabis is not permitted
(c) Data centers. Data centers are subject to the following standards:
(1) Data centers in both the I and AP districts are subject to the following standards:
(i) Application. A conditional use permit application for a data center shall include the
following:
(a) A written technical study prepared by a registered professional engineer that
describes the existing capacity of the water system, the proposed water system
demands for the data center, and a description of the impact of the data center on private
and municipal utilities. If required by city staff, a cost estimate shall be provided to
mitigate the impacts of water usage by the center. Before the study is commenced, the
applicant shall receive city staff approval of the professional engineer that they are
requesting to use to complete the study. The cost of the study shall be borne by the
applicant, and the results of the study shall be subject to review and approval by city
staff for the conditional use permit to be approved.
(b) Written statement that the data center will not exceed the capacity of the existing
electrical grid or supply system. If grid or system improvements are necessary, the cost
for the improvements will be borne by the owner of the data center and not by the local
rate payers.
(c) A sound mitigation plan that describes noise impacts from both the interior and
exterior equipment and the plan to mitigate those impacts. Before the writing of the plan
is commenced, the applicant shall receive city staff approval of the consultant that they
are requesting to use to complete the plan. The cost of the plan development shall be
borne by the applicant, and the plan shall be subject to review and approval by city staff
for the conditional use permit to be approved.
(d) Documentation that the private utility companies have been notified of the
proposed conditional use permit application.
(ii) Mechanical equipment. Mechanical equipment for a data center shall be located either
in the building or on the building’s rooftop. If on a rooftop, the equipment shall meet
the screening requirements of the Crystal city code, subsection 520.13.
(iii) Residential buffer. The building and external equipment serving the data center shall
be at least 100 feet from the property line of an abutting or adjacent residential use.
(2) Data centers in the I district are subject to the following additional standard:
88
CR225-464-620540.v15
(i) The floor area for the data center shall be limited to no more than 100,000 gross square
feet per property.
(3) Data centers in the AP district are subject to the following additional standard:
(i) The floor area for the data center shall be limited to no more than 200,000 gross square
feet per property.
(c) (d) Industrial or commercial uses with outdoor storage of parts, products, or fuels. Industrial
uses with outdoor storage of parts, products or fuels are subject to the following standards:
(1) The storage or parking area is hard surfaced, clearly designated on the site as being limited
to the specific, approved area, and meets the relevant requirements as provided in the
Crystal city code, subsection 520.15 for hard surface design;
(2) The storage or parking area does not exceed 100% of the gross floor area of the principal
building, 50% of the area of the property, or 10,000 square feet, whichever is less;
(3) The storage or parking area is prohibited in the front or corner side yard;
(4) The storage or parking area is subject to the screening requirements of the Crystal city
code, subsection 520.13; and
(5) The applicant must obtain zoning certificate approval for the storage or parking area.
Subd. 6. Public facilities, telecommunications and utilities use category.
(a) Public utility buildings. Equipment and materials are completely enclosed in a permanent
building with no outside storage, unless in compliance with the screening requirements of this
UDC.
(b) Telecommunications towers.
(1) Findings. The Federal Communications Act of 1934 as amended by the
Telecommunications Act of 1996 (“the Act”) grants the Federal Communications
Commission (FCC) exclusive jurisdiction over the regulation of the environmental effects
of radio frequency emissions from telecommunications facilities and the regulation of radio
signal interference among users of the radio frequency spectrum. By this subsection, the
city intends to exercise the full scope of its authority under the Act and under state law
regarding the regulation of towers and telecommunications facilities in the city. Consistent
with the Act, the regulation of towers and telecommunications facilities in the city will not
have the effect of prohibiting any person from providing wireless telecommunications
services.
(2) Purpose. The general purpose of this subsection is to regulate the placement, construction
and modification of telecommunication towers and facilities in order to protect the health,
safety and welfare of the public, while not unreasonably interfering with the development
of the competitive wireless telecommunications marketplace in the city. Specifically, the
purposes of this subsection are:
(i) To regulate the location of telecommunication towers and facilities;
(ii) To protect residential areas and land uses from potential adverse impacts of
telecommunication towers and facilities;
96
CR225-464-620540.v15
Subd. 1. Purpose. This subsection authorizes accessory uses and structures that are incidental and
customarily subordinate to principal uses. The intent of this subsection is to allow accessory uses while not
creating adverse impacts on surrounding lands.
Subd. 2. General provisions.
(a) Table 4 lists the accessory uses allowed within all zoning districts except for the overlay zoning
districts. Except for the TC-PD district which has separate requirements, the uses permitted in
the overlay districts shall be controlled by the underlying base zoning district.
(b) Small accessory uses such as arbors, benches, doghouses, play sets, garden decorations,
pergolas, and firewood cribs (wood piles) are exempt from the provisions of this subsection,
but cannot be located in public rights-of-way. Additional requirements for firewood cribs are
located in the Crystal city code, subsection 605.13.
(c) Tents, play houses, or similar structures shall not be used as temporary or permanent dwelling
units, but may be used for recreational purposes.
(d) Accessory structures shall only be constructed concurrent with or after the construction of the
principal building on the same site.
(e) Uses and structures that are accessory to a conditional principal use shall be permitted in
accordance with this subsection, without requiring a conditional use permit amendment, unless
specifically required as a condition of the conditional use permit approval.
Subd. 3. Explanation of table of permitted uses.
(a) Symbols in table. The symbols used in Table 4 are defined as follows:
(1) Permitted uses (P). A “P” in a cell indicates that a use type or structure is allowed by-right
in the respective zoning district subject to compliance with the use-specific standards set
forth in the final “use-specific standards” column of Table 4. Permitted uses are subject to
all other applicable standards of this UDC;
(2) Conditional uses (C). A “C” in a cell indicates that a use type or structure is allowed as a
conditional use in the respective zoning district subject to compliance with the use-specific
standards set forth in the final “use-specific standards” column of Table 4 and approval of
a conditional use permit in accordance with the Crystal city code, subsection 510.19.
Conditional use permits are subject to all other applicable standards of this UDC;
(3) Prohibited uses (-). A cell with a “-" indicates that the listed use type or structure is
prohibited in the respective zoning district;
(4) Use-specific standards. The “use-specific standards” column of Table 4 cross-reference
standards that are specific to an individual use type or structure and are applicable to that
use or structure in all districts unless otherwise stated in the use-specific standards; and
(5) Unlisted uses. If an application is submitted for a use or structure that is not listed in Table
4, the use is not permitted. The applicant may submit an application for an amendment to
the text of this UDC according to the requirements of the Crystal city code subsection
510.29. zoning administrator is authorized to classify the new or unlisted use or structure,
with consultation from appropriate city departments, into an existing use or structure type
that most closely fits the new or unlisted use. If no similar use determination can be made,
97
CR225-464-620540.v15
the zoning administrator shall refer the use to the planning commission, who may initiate
an amendment to the text of this UDC to clarify where and how the use should be permitted.
Table 4: Permitted Accessory Uses and Structures
Use Category and Use Type
P = Permitted Use
C = Conditional Use
- = Not Permitted
Base Zoning
Districts
Zoning
Certificate
Required
Use-Specific Standards
in Subsection: R-1 R-2 R-3 NC C TC IAP
Accessory Uses
Assembly or gathering space - - - P P P P - No 515.23, subdivision 2 (a)
Day Care Facilities, In home P P P - - P - - No
Drive-through facilities - - - - C - - - Not Applicable 515.23, subdivision 2 (b)
Home Businesses P P P - - P - - No 515.23, subdivision 2 (c)
Keeping of Chickens P P - - - - - - No 910
Kennels, Commercial P - - - - - - - No 515.23, subdivision 2 (d)
Kennels, Multiple Animal P P P - - - - - No 515.23, subdivision 2 (e)
Retail sale of cannabis
products, off-sale liquor, or
tobacco products
- - - - P P P - No See Note [4]
Accessory Structures
Accessibility ramps P P P P P P P P No 515.23, subdivision 3 (a)
Accessory dwelling units P P - C - - - - Yes 515.23, subdivision 3(b)
Amateur radio towers P P P - - - - P No 515.23, subdivision 3(c)
Balconies - P P P - P - - No 515.23, subdivision 3 (d)
Carports P P - - - - - - No 515.23, subdivision 3(h)
Clothesline poles P P - - - - - - No 515.23, subdivision 3(e)
Commercial storage buildings - - - - C - P P See Note [1] 515.23, subdivision 3(f)
Fences and walls P P P P P P
[2] P P No 520.09
Flagpoles P P P P P P P P No
Fuel pumps, private use - - - - P - P P No 515.23, subdivision 3 (g)
Garages, attached or detached P P P P P - P P No 515.23, subdivision 3(h)
Gazebos P P P - - - - - No 515.23, subdivision 3(i)
Mechanical equipment P P P P P P P P 520.13
Micro dwelling units C C C C C - C - Not
Applicable 515.23, subdivision 3 (j)
Noncommercial greenhouses P P - - - - - - No 515.23, subdivision 3(k)
Off-street parking and loading
[3] P P P P P P P P Yes 520.15
Patios, decks, and porches P P P P P P - - No 515.23, subdivision 3 (l)
Sheds P P P P P - P P No 515.23, subdivision 3(m)
100
CR225-464-620540.v15
(5) A home business may be located within the dwelling, an accessory building, or both,
provided that the total area of the home business is not greater than 50% of the finished
floor area of the dwelling;
(6) Such home business shall not require internal or external alterations or involve construction
features not customarily found in dwellings;
(7) There shall be no exterior storage or display of equipment, goods or materials used in the
home business; and
(8) One sign, as allowed in Table 14 may be placed on the property, not to exceed six square
feet in area., may be placed on the premises. The sign may identify the home business,
resident name, address, website, and email address or phone number, but may contain no
other information. The sign may not be illuminated and must be set back a minimum of ten
feet from a property line abutting a public street. If the sign is freestanding, the total height
may not exceed five feet.
(d) Kennels, commercial. Commercial kennels are subject to the following standards:
(1) In the R-1 zoning district, commercial kennels shall only be allowed at one-family
dwellings, and the use of the commercial kennel is limited to raising, selling, boarding,
breeding, and grooming of dogs or other animals; and
(2) Commercial kennels shall adhere to the requirements for home businesses in this
subsection.
(e) Kennels, multiple animal. If a multiple animal kennel is operated as a home business, it shall
adhere to the requirements for home businesses in this subsection.
(f) Sale of cannabis products, off-sale liquor, and tobacco products. Any retail establishment that
sells cannabis products, off-sale liquor, or tobacco products at retail as an accessory use to its
principal use is subject to the following standards:
(1) The sale of such products shall only be accessory to, and occur within, a retail
establishment. If a retail establishment derives more than 50% of its gross revenue from
the sale of any one of these products, such sales cannot be considered an accessory use and
the retail establishment must obtain all permits or permissions required to sell the product
as its principal use.
(2) The retail establishment must possess such licenses as may be required to sell such
products.
(3) The sale of such products is only allowed if the lot containing the retail establishment is
located outside the buffers identified in Crystal city code subsection 515.19, subdivision 4
(i) (5).
(4) If the retail establishment is selling cannabis products, it must be registered with the city
in accordance with Minnesota Statutes, section 342.22 and the procedures established by
the city.
Subd. 3. Accessory structures.
103
CR225-464-620540.v15
(5) The architectural style is compatible with the principal building and surrounding land
uses. Commercial storage buildings in the commercial and industrial districts shall
also comply with the following standards: Exterior building design and materials shall
comply with the provisions as provided in the Crystal city code, subsection 520.05;
and
(i) The storage building shall not be constructed of the following materials: fabric,
canvas, concrete block, unadorned prestressed concrete panels, plastic sheets,
tarps, unfinished or corrugated metal, exposed plywood, particle board, or similar
materials; and.
(ii) Blank walls are prohibited.
(6) The use will not conflict with the character of development intended for the zoning
district.
(g) Fuel pumps, private use. Private fuel pumps for use by commercial businesses are allowed,
provided that the current business, or its successor business, only uses the fuel pumps for its
vehicles and equipment and does not allow them to be used by the general public. For the
purposes of this UDC, private fuel pumps do not include those fuel pumps in use by a vehicle
fuel sales business as allowed in Table 3.
(h) Garages and carports. Garages and carports are subject to the following standards:
(1) Attached and detached garages are subject to the following standard:
(i) Garages shall be accessed through a vehicular entrance door with an opening not
less than seven feet wide and seven feet high. A garage shall be no less than nine
feet wide and eighteen feet long, measured as the continuous clear space between
the insides of the interior walls or wall framing if unfinished.
(2) Attached and detached garages and carports are subject to the following standard:
(i) Garages and carports shall have a floor constructed of poured concrete in
accordance with standards approved by the city engineer and building official.
(3) Detached garages and carports are subject to the following standards:
(1) For one and two family dwellings, the cumulative area of all detached accessory
buildings on the property shall not exceed the finished floor area of the residential
portion of the principal building;
(2) For multiple family dwellings, detached garages shall be designed to meet the
minimum number of required parking spaces and required setbacks. To the extent
practicable, garages shall be located to the side or rear of the building; and
(3) Garages and carports shall not be constructed of the following materials: fabric,
canvas, concrete block, cloth, plastic sheets, tarps, unfinished or corrugated metal,
exposed plywood, particle board, or similar materials.
(i) Gazebos. Gazebos are subject to the following standards:
(1) The cumulative area of all detached accessory buildings on the property shall not
exceed the finished floor area of the residential portion of the principal building; and
104
CR225-464-620540.v15
(2) Gazebos shall not be constructed of the following materials: fabric, canvas, concrete
block, cloth, plastic sheets, tarps, unfinished or corrugated metal, exposed plywood,
particle board, or similar materials.
(j) Micro unit dwellings. Micro unit dwellings are subject to the following standards:
(1) Each unit shall not exceed a gross floor area of 400 square feet;
(2) Micro unit dwellings shall be included in the residential density calculation for the
zoning district in which it is located;
(3) Micro unit dwelling shall be constructed as to be compatible in composition,
appearance, and durability with the exterior materials of the principal building of the
religious institution;
(4) The residents of each dwelling unit shall have access to water and electric utilities
either by connecting the units to utilities serving the principal building of the religious
institution or by providing residents access to permanent common kitchen facilities and
common facilities for toilet, bathing, and laundry within the principal building.
(5) An application for a conditional use permit shall contain a written plan approved by
the religious institution’s governing board that outlines the information in Minnesota
Statutes, section 327.30, subdivision 3 (b).
(6) For any city-approved micro dwelling unit, the religious institution shall annually
certify to the city that it has complied with the eligibility requirements for residents in
Minnesota Statutes, section 327.30, subdivision 1.
(k) Noncommercial greenhouses. Noncommercial greenhouses are subject to the following
standards:
(1) Shall be located in the rear yard;
(2)(1) Shall be limited to one per property; and
(3)(2) The cumulative area of all detached accessory buildings on the property shall not
exceed the finished floor area of the residential portion of the principal building; and.
(4)(3) Noncommercial greenhouses shall not be constructed of the following materials:
fabric, canvass, concrete block, cloth, plastic sheets, tarps, unfinished or corrugated
metal, exposed plywood, particle board, or similar materials.
(l) Patios, decks and porches. Within the TC district, porches and decks are not permitted.
(m) Sheds. Sheds are subject to the following standards:
(1) The cumulative area of all detached accessory buildings on the property shall not
exceed the finished floor area of the residential portion of the principal building; and
(2) Sheds shall not be constructed of the following materials: fabric, canvas, concrete
block, cloth, plastic sheets, tarps, unfinished or corrugated metal, exposed plywood,
particle board, or similar materials.
(n) Sidewalks. Sidewalks are subject to the following standards:
107
CR225-464-620540.v15
(d) Permit required. The “permit required” column defines if the proposed temporary use or
structure requires approval of a zoning certificate or other permit;
(e) Use-specific standards. The “use-specific standards” column of Table 5 cross-reference
standards that are specific to an individual use type and are applicable to that use in all districts
unless otherwise stated in the use-specific standards; and
(f) Unlisted uses. If an application is submitted for a use that is not listed in Table 5, \the use is
not permitted. The applicant may submit an application for an amendment to the text of this
UDC according to the requirements of the Crystal city code subsection 510.29. zoning
administrator is authorized to classify the new or unlisted use, with consultation from
appropriate city departments, into an existing use type that most closely fits the new or unlisted
use. If no similar use determination can be made, the zoning administrator shall refer the use
to the planning commission, who may initiate an amendment to the text of this UDC to clarify
where and how the use should be permitted.
108
CR225-464-620540.v15
Table 5: Permitted Temporary Uses and Structures
Use Category and Use Type
P = Permitted Use
- = Not Permitted
Base Zoning Districts R-1 R-2 R-3 NC C TC I AP Allowable
Duration (per
site)
Permit
Required
Use-Specific
Standards in
Section:
Construction Dumpster
P P P P P P P P
No more than
three consecutive
months in any
12-month period
See city code
section 605
515.27,
subdivision 2;
605
Construction site office
Structure shall be
removed within
15 days of the
issuance of the
certificate of
occupancy
No
Garage/Yard Sales
P P P - - - - -
Maximum of
three consecutive
days, four times
per calendar year
per site
No 515.27,
subdivision 3
Outdoor dining [1]
P P P P P P P P 270 days per site
per calendar year
Zoning
Certificate
(Type 1
Review) [2]
515.27,
subdivision 4
Outdoor sales [1]
- - - P P P P - 270 days per site
per calendar year
Zoning
Certificate
(Type 1
Review)
515.27,
subdivision 5
Portable Storage Container P P P P P - P P 60 days per site
per calendar year No 515.27,
subdivision 6
Signs, Temporary P P P P P P P P See section 530 Sign Permit 530
Notes:
1. Outdoor seating for cafes or restaurants or outdoor sales areas for retail establishments that exceed the temporary
use duration time limits would require a conditional use permit.
2. A zoning certificate is not required for a mobile food unit.
515.27. Use-specific standards for temporary uses and structures.
Subd. 1. Purpose and applicability.
(a) This subsection provides site planning and/or operating standards for certain land uses that are
permitted in Table 5.
109
CR225-464-620540.v15
(b) The land uses and activities covered by this subsection shall comply with the applicable
standards for the specific use in all districts unless otherwise specified, in addition to all other
applicable provisions of this UDC.
Subd. 2. Construction dumpsters. Construction dumpsters are subject to the following standards:
(a) If the dumpster is located in the public right-of-way, the dumpster shall comply with the
requirements of the Crystal city code, chapter VIII; and
(b) If the dumpster is located on private property, the dumpster shall be located to the side or rear
of the site, but away from principal buildings on adjacent properties, to the extent practicable.
Subd. 3. Garage or yard sales. Garage or yard sales are subject to the following standards:
(a) Hours of operation for the garage or yard sale are limited to between 8:00 a.m. and 9:00 p.m.;
and
(b) Garage or yard sale signs identifying the location and times of a sale may be placed on the
property at which the sale is to be conducted or on the property of others with their consent.
Such signs shall not exceed 4 square feet in area per side; shall not be placed on or attached to
any public property or utility pole; shall not be placed within the sight triangle as required in
the Crystal city code, chapter VIII; and must be removed within 24 hours of the time stated on
such sign for the conclusion of the sale.
Subd. 4. Outdoor dining. Outdoor dining is subject to the following standards:
(a) Mobile food units. Mobile food units are subject to the requirements in the Crystal city code,
chapter XIII;
(b) Outdoor seating dining for cafes or restaurants or eating establishments. If a restaurant or eating
establishment has Outdoor outdoor seating dining, that use for cafes and restaurants is subject
to the following standards:
(1) An outdoor dining area may be allowed accessory and incidental to a restaurant with indoor
eating area on the same site provided that the outdoor eating area shall comply with the
parking requirements in Table 11 of the Crystal city code, subsection 520.15;
(2) Outdoor dining areas shall be designated on a site plan submitted for the zoning certificate
application;
(3) If no grade separation is provided between vehicular traffic and the outdoor dining area,
permanent railings or fencing shall be provided around the dining area. If the outdoor
dining area is adjacent to a sidewalk or other facility that is closed to vehicular traffic, no
railing or fencing shall be required;
(4) Umbrellas, or other protective elements, that shelter diners from the elements shall be
secured so as not to create a hazard;
(5) Enclosing an outdoor dining area either by a permanent roof or to expand the existing
structure shall meet all the requirements of a building within the applicable zoning district;
and
(6) Within the TC and TC-PD districts, outdoor dining may encroach into setback areas or the
public right-of-way, provided that the sidewalk remains clear to a width of five feet.
115
CR225-464-620540.v15
Figure 14: Illustration of typical setback locations for a one-family dwelling
(a) Front setbacks. A front setback shall be measured at right angles from the nearest point on the
public right-of-way at the front of the parcel to the nearest point of the wall of the structure,
except as provided for in this subsection.
(b) Side setbacks. The side setback shall be measured at right angles from the nearest point on the
side property line of the parcel to the nearest point of the wall of the structure, establishing a
setback line parallel to the side property line, which extends between the front and rear setbacks
(see Figure 14).
(c) Rear setbacks. The rear setback shall be measured at right angles from the nearest point on the
rear property line to the nearest part of the structure, establishing a setback line parallel to the
rear property line (see Figure 14).
(d) Corner lots. The corner side setback shall be measured from the nearest point of the wall of the
structure to the nearest point of the wall of the structure. (see Figure 14)
Subd. 5. Height requirements and exceptions.
(a) Standards. Each structure shall comply with the height requirements of the applicable zoning
district, except:
(1) As allowed in Table 6 when a building feature encroaches into a required height; and
(2) The height of telecommunications facilities, including antennas, poles, towers, and
necessary mechanical appurtenances, shall comply with the Crystal city code, subsection
515.19.
(3) The following required standards are intended to preserve daylight and solar access for
residential uses.
(i) Prohibited shadows. New buildings shall not exceed a height that would cast shadows
on existing residential uses at both 10:00 a.m. and 2:00 p.m. central standard time on
December 21.
116
CR225-464-620540.v15
(ii) Shadow analysis. Any relevant development review application shall include a shadow
analysis for a new building that may impact adjacent residential uses. The shadow
analysis shall include a site plan showing the proposed building, surrounding
residential uses, and the shadow cast by the proposed building(s) at both 10:15 a.m.
and 2:15 p.m. on December 21. The shadow analysis shall take into account differences
in topography and shall assume the following:
Time on December 21 Solar Azimuth Shadow Length
10:15 a.m. Standard time 152.12 degrees 3.38 x building height
2:15 p.m. Standard time 199.76 degrees 3.48 x building height
(b) Measurement of building height. The maximum allowable building height shall be measured
in feet as the vertical distance from the average grade around the perimeter of a structure to
(see Figure 15):
(5) The deck line of a mansard roof; or
(6) The highest point of a flat roof; or
(7) The mean height between the eaves and highest point on gable, hip or gambrel roof.
The location of average grade shall be determined by the zoning administrator and shall not be
artificially raised to gain additional building height.
Figure 15: Illustration of height measurement
(c) FAA requirements. Height requirements shall meet the requirements of the Federal Aviation
Administration (FAA).
(1) Notice to the Federal Aviation Administration using FAA form 7460-1 is required prior to
the following:
121
CR225-464-620540.v15
(a) Site development standards for principal buildings. Table 7 are the regulations for residential
densities, setbacks, number of principal buildings, lot dimensions, building height, and green
space for placing principal buildings in the city’s zoning districts.
(b) Site development standards for accessory structures. Table 8 are the setback and height
requirements for placing accessory structures in the city’s zoning districts.
Table 7: Zoning District Site Development Standards for Principal Buildings
R1 R2 R3 NC Commercial TC Industrial AP
Permitted Residential Density
Permitted
Residential
Density
No more
than 6 8
units per
acre
(gross)
6 to 16 20
units per acre
(gross)
16 to 40 50
units per
acre (gross)
16 to 40
units per
acre
(gross)
Not
Applicable
25 to 80
units per
acre
(gross)
Not
Applicable
Not
Appli-
cable
Minimum Building Setbacks [1]
Front 30 feet 30 feet 30 feet
10 feet
10 feet
1 foot
minimum
10 foot
maximum
10 feet
200’ from
resi-
dential use
Side 5 feet 10 feet 15 feet
10 feet 10 feet
0 foot
minimum 10 feet
200’ from
resi-
dential use
Rear 30 feet 30 feet 30 feet
10 feet 10 feet
5 foot
minimum 10 feet
200’ from
resi-
dential use
Corner Side 10 feet [2] 30 feet 30 feet 10 feet 10 feet
2 foot
minimum
12 foot
maximum
10 feet
200’ from
resi-
dential use
Number of Principal Buildings
Maximum
number of
principal
buildings per
property
One One One
One
One
Not
Applicable
One
Not
Appli-
cable
Minimum Lot Area
One-family
Detached
Dwelling
6,000 SF 6,000 SF Not
Applicable
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Two-Family
Dwelling 10,000 SF 10,000 SF 10,000 SF
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Other
Residential
Uses
Not
Applicable 10,000 SF 20,000 SF
10,000 SF Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
122
CR225-464-620540.v15
Table 7: Zoning District Site Development Standards for Principal Buildings
R1 R2 R3 NC Commercial TC Industrial AP
Non-
Residential
Uses [3]
Not
Applicable
Not
Applicable Not Applicable
10,000 SF
20,000 SF
Not
Applicable 20,000 SF
Not
Appli-
cable
Minimum Lot Depth
One-family
Detached
Dwelling
100 feet 100 feet 100 feet
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Two-Family
Dwelling 100 feet 100 feet 100 feet
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Other
Residential
Uses
Not
Applicable 100 feet 100 feet
100 feet Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Non-
Residential
Uses [3]
100 feet 100 feet 100 feet
100 feet
120 feet
Not
Applicable 120 feet
Not
Appli-
cable
Minimum Lot Width
One-family
Detached
Dwelling
50 feet 50 feet Not
Applicable
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Two-Family
Dwelling 80 feet 80 feet Not
Applicable
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Other
Residential
Uses
Not
Applicable 100 feet 100 feet
100 feet Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Non-
Residential
Uses [3]
100 feet 100 feet 100 feet
100 feet
100 feet
Not
Applicable 100 feet
Not
Appli-
cable
Maximum Building Height
One-family
Detached
Dwelling
2 stories or
32 feet,
whichever
is less
2 stories or
32 feet,
whichever is
less
Not
Applicable
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Two-Family
Dwelling
2 stories or
32 feet,
whichever
is less
2 stories or
32 feet,
whichever is
less
2 stories or
32 feet,
whichever is
less
Not
Applicable Not
Applicable
Not
Applicable Not
Applicable
Not
Appli-
cable
Other
Residential
Uses
Not
Applicable
3 stories or
40 feet,
whichever is
less
5 stories
or 60 feet,
whichever is
less
3 stories,
or 40 feet,
whichever
is less
Not
Applicable
5 stories
or 60 feet,
whichever
is lessNot
Applicable
Not
Applicable
Not
Appli-
cable
Non-
Residential
Uses [3]
2 stories
or 32 feet,
whichever
is less
3 stories or
40 feet,
whichever is
less
5 stories
or 60 feet,
whichever is
less
3 stories,
or 40 feet,
whichever
is less
5 stories
or 60 feet,
whichever is
less
5 stories
or 60 feet,
whichever
is lessNot
Applicable
5 stories
or 60 feet,
whichever
is less
3 stories
or 40 feet,
which-
ever is
less
Minimum Green Space [4]
124
CR225-464-620540.v15
Table 8: Zoning District Site Development Standards for Accessory Structures
Accessory
Structure Type R1 R2 R3 NC Commercial TC Industrial AP
Amateur radio
towers
See note
[1], below
See note
[1], below
See note
[1], below
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
See note
[1],
below
Attached Decks
and open porches
Front: 30
feet
Side: 3 5
feet
Rear: 30
feet
Corner
side: 10
feet
Front: 30
feet
Side: 15
feet
Rear: 30
feet
Corner
side: 30
feet
Front: 30
feet
Side: 15
feet
Rear: 30
feet
Corner
side: 30
feet
Front: 10
feet
Side: 10
feet
Rear: 15
feet
Corner
side: 10
feet
Front: 30
feet
Side: 10
feet
Rear: 3
feet
Corner
side: 30
feet
Not
Applicable
Not
Applicable
Not
Appli-
cable
Clothesline Poles Front: Not
allowed
Side: 3
feet
Rear: 3
feet
Corner
side: 10
feet
Front: Not
allowed
Side: 3 feet
Rear: 3 feet
Corner
side: 10
feet
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Appli-
cable
Commercial
Storage Buildings
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Front: 30
feet
Side: 10
feet
Rear: 3 feet
Corner
side: 30
feet
Not
Applicable
Front: 30
feet
Side: 10 feet
Rear: 3 feet
Corner side:
30 feet
Front: 30
feet
Side: 10
feet
Rear: 3
feet
Corner
side: 30
feet
Detached decks Front: 30
feet
Side: 3
feet
Rear: 3
feet
Corner
side: 10
feet
Front: 30
feet
Side: 5 feet
Rear: 5 feet
Corner
side: 10
feet
Front: 30
feet
Side: 5
feet
Rear: 5
feet
Corner
side: 10
feet
Front: 10
feet
Side: 10
feet
Rear: 15
feet
Corner
side: 10
feet
Front: 30
feet
Side: 10
feet
Rear: 10 feet
Corner
side: 15
feet
Not
Applicable
Not
Applicable
Not
Appli-
cable
126
CR225-464-620540.v15
Table 8: Zoning District Site Development Standards for Accessory Structures
Accessory
Structure Type R1 R2 R3 NC Commercial TC Industrial AP
Noncommercial
greenhouses
Front:
Not
Applicable
30, but
cannot be
closer to
the street
than the
principal
building
Side: 3
feet
Rear: 3
feet
Corner
side: 10
feet
Front: Not
Applicable
Side: 3 feet
Rear: 3 feet
Corner
side: 10
feet
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Appli-
cable
Patios Front: 30
feet
Side: 1
foot
Rear: 1
foot
Corner
side: 10
feet
Front: 30
feet
Side: 1 foot
Rear: 1
foot
Corner
side: 10
feet
Front: 30
feet
Side: 5
feet
Rear: 3
feet
Corner
side: 30
feet
Front: 5
feet
Side: 5 feet
Rear: 15
feet
Corner
side: 5 feet
Front: 30
feet
Side: 10
feet
Rear: 3
feet
Corner
side: 30
feet
Not
Applicable
Not
Applicable
Not
Appli-
cable
Sheds Front: 30
feet, but
cannot be
closer to
the street
than the
principal
building
[2]
Side: 3
feet
Rear: 3
feet
Corner
side: 10
feet
Front: 30
feet, but
cannot be
closer to
the street
than the
principal
building
Side: 3 feet
Rear: 3 feet
Corner
side: 10
feet
Front: 30
feet, but
cannot be
closer to
the street
than the
principal
building
Side: 3
feet
Rear: 3
feet
Corner
side: 10
feet
Front: 30
feet, but
cannot be
closer to
the street
than the
principal
building
Side: 10
feet
Rear: 10
feet
Corner
side: 30
feet
Front: 30
feet, but
cannot be
closer to
the street
than the
principal
building
Side: 10
feet
Rear: 3
feet
Corner
side: 30
feet
Not
Applicable
Front: 30
feet, but
cannot be
closer to the
street than
the principal
building
Side: 3
feet
Rear: 3
feet
Corner side:
10 feet
Front: 30
feet, but
cannot be
closer to
the street
than the
princi-pal
build-ing
Side: 5
feet
Rear: 5
feet
Corner
side: 10
feet
Solar energy
systems
See note
[5], below
See note
[5], below
See note
[5], below
See note
[5] below
See note [5],
below
See note
[5], below
See note [5],
below
See note
[5],
below
128
CR225-464-620540.v15
Table 8: Zoning District Site Development Standards for Accessory Structures
Accessory
Structure Type R1 R2 R3 NC Commercial TC Industrial AP
Accessory
dwelling units,
detached
22 feet 22 feet Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Appli-
cable
Amateur radio
towers
Tower
not to
exceed
75 feet
Tower
not to
exceed
75 feet
Tower
not to
exceed
75 feet
Not
Applicable
Not
Applicable
Tower
not to
exceed
75 feet
Tower
not to
exceed
75 feet
Tower
not to
exceed
75 feet
Commercial
storage buildings
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
Not
Applicable
20 feet 20 feet 25 feet
Detached
accessory
buildings [6]
15 feet 15 feet 15 feet 15 feet Not
Applicable
15 feet 15 feet 15 feet
Essential services
(such as poles or
towers)
As
determined
by the city
engineer
As
determined
by the city
engineer
As
determined
by the city
engineer
As
determined
by the city
engineer
As
determined
by the city
engineer
As
determined
by the city
engineer
As determined
by the city
engineer
As deter-
mined by
the city
engineer
Fences See
subsection
520.09
See
subsection
520.09
See
subsection
520.09
See
subsection
520.09
Not
Applicable
See
subsection
520.09
See
subsection
520.09
See sub-
section
520.09
Flagpoles 25 feet 25 feet 25 feet 25 feet 25 feet 25 feet 25 feet 25 feet
Satellite dishes Not to
exceed 4
feet above
the roof
Not to
exceed 4
feet above
the roof
Not to
exceed 4
feet
above
the roof
Not to
exceed 4
feet above
the roof
Not to
exceed 4 feet
above the
roof
Not to
exceed 4
feet
above
the roof
Not to
exceed 4
feet
above
the roof
Not to
exceed 4
feet
above
the roof
Solar energy
systems
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Freestanding:
20 feet
when
oriented at
maximum
tilt
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Freestanding:
20 feet
when
oriented at
maximum
tilt
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Freestanding:
20 feet
when
oriented at
maximum
tilt
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Freestanding:
20 feet
when
oriented at
maximum
tilt
Building
mounted:
Shall not
exceed the
maximum
allowed
building
height
Freestanding:
20 feet
when
oriented at
maximum
tilt
Building
mount-
ed: Shall
not
exceed
the maxi-
mum
allowed
building
height
Free-
standing:
20 feet
when
oriented at
maxi-mum
tilt
Television and
Radio Antennae
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet above
the roof
Not to
exceed 12
feet
above the
roof
129
CR225-464-620540.v15
Table 8: Zoning District Site Development Standards for Accessory Structures
Accessory
Structure Type R1 R2 R3 NC Commercial TC Industrial AP
NOTES:
[1] The tower shall be located only in the rear yard, and set back at least 15 feet from any property line. However,
necessary guy wires, anchors, and wires of less than 1/4 inch may be set back at least 3 feet from any rear or
interior side property line.
[2] On interior lots abutting directly on Twin Lake, a detached accessory garage, carport, shed, accessory dwelling
unit, or workshop may be erected within the front setback area provided it does not encroach into the required
front, side or corner side setback.
[3] Garages, carports, accessory dwelling units, or workshops in the side or rear yard may be located as close as 3
feet to the property line provided that no part of the building, including eaves and foundation, is within the 3 foot
area and does not encroach into a platted or dedicated easement.
[4] If the vehicle entrance for a detached garage or carport faces a street or alley, the garage or carport shall be at
least 20 feet from the corner side or rear property line.
[5] For building-mounted solar energy systems, the collector surface and mounting devices shall not extend beyond
the required setbacks on which the building is mounted. For freestanding solar energy systems, the system may
not extend into the following setbacks when oriented at minimum design tilt:
Front: 30 feet, but cannot be located closer to the street than the principal building; Side: 5 feet; Rear: 5 feet;
Corner side: 10 feet.
[6] For the purposes of this maximum height requirement, detached accessory buildings are defined as carports,
detached garages, gazebos, noncommercial greenhouses, sheds and workshops.
Some of these structures may not be allowed in every zoning district.
520.05 Architectural design standards for principal buildings.
Subd. 1. Intent. It is not the intent of the city to unduly restrict design freedom when reviewing
project architecture in connection with a site plan for a principal building. However, it is in the best interest
of the city to promote high standards of architectural design and compatibility with surrounding structures
and neighborhoods.
Subd. 2. Exterior design and materials. Except for warehouse and industrial buildings that are
adequately screened from view, the following are not allowed for building exteriors:
(a) Except for airplane hangars and data centers in the AP district, Blank blank walls;
(b) Unadorned prestressed concrete panels;
(c) Concrete block; and
(d) Unfinished metal and corrugated metal, except for airplane hangars at the Crystal Airport which
may have a corrugated metal exterior.
520.07. Exterior lighting.
Subd. 1. Standards. Exterior lighting is subject to the following standards:
(a) Any exterior lighting that is used to illuminate an off-street parking area, sign or other structure
shall be hooded or controlled in some manner so as to deflect light away from any adjoining
residential property or from public streets;
130
CR225-464-620540.v15
(b) Exterior lighting which casts light on a public street shall not exceed one foot candle at the
property line abutting the street and lighting which casts light on residential property shall not
exceed 0.4 foot candle at the property line abutting that residential property; and
(c) Bare light bulbs shall not be permitted if they can be viewed from adjacent property or the
public right-of-way.
520.09. Fences and retaining walls.
Subd. 1. Fence requirements.
(a) Height requirements.
(1) Measurement of fence height. The height of a fence shall be measured as follows:
(i) Fence height is measured from the average grade to the tallest part of the fence,
including posts;
(ii) In cases where the fence is located on sloped grade, the fence height shall be measured
separately for each segment between posts; and
(iii) In the case of grade being changed where the fence is to be located, such as when fill
is added or berm is created, the maximum fence height shall be measured from the
grade at the principal structure or the property line, whichever is closer to the proposed
fence.
(2) Fences in residential districts. Fences in residential districts shall comply with the
following:
(i) For interior lots, fences shall not be taller than 4.5 feet in the front yard and 6.5 feet in
the side or rear yard (see Figure 16); and
Figure 16: Fence height on interior residential lot
(ii) For fences on corner lots, a the fence height in the front and corner side yards is
determined by which side the principal building faces (see Figures 17 and 18) property
owner may choose which yard will have a 6.5 foot tall fence provided that no fence
131
CR225-464-620540.v15
will exceed 4.5 feet in height in any yard between the front entry of the principal
building and any public street (see Figures 17 and 18).
Figure 17: Fence location on corner residential lot (principal building facing shorter side)
Figure 18: Fence location on corner residential lot (principal building facing longer side)
(3) Fences in non-residential districts. Fences in non-residential districts, including the TC-
PD district, shall comply with the following:
(i) For interior lots, fences shall not be taller than 4.5 feet in the front yard and 8.5 feet in
the side or rear yard; and
(ii) For corner lots, fence height is determined in the same manner as for corner residential
lots (see Figures 17 and 18), except that the maximum height shall be 8.5 feet where a
6.5 feet fence is allowed.
145
CR225-464-620540.v15
Traffic into and out of business areas shall to the maximum extent possible, be forward moving
with no backing into streets.
(f)Off-street parking of motor vehicles and recreational vehicles and equipment. Motor vehicles
and recreational vehicles and equipment may be parked or stored outside as provided in the
Crystal City Code, chapter 13. If parked or stored outside, motor vehicles and recreational
vehicles and equipment shall have current valid registration including clearly visible license
plate tabs. One-and-two family dwellings and lawful Lawful vehicle sales businesses in
commercial or industrial districts are exempt from this requirement.
Subd. 4. Rules for computation.
(a)Calculation. The following rules shall apply when computing parking spaces:
(1)Driveway space meeting parking requirements. Entrances, exits, or driveways shall not be
computed as any part of a required parking lot or area, except in the case of one or two
family dwellings where driveways may be used in calculating the amount of off-street
parking;
(2)Multiple uses. Unless otherwise noted or approved, off-street parking areas serving more
than one use shall provide parking in an amount equal to the combined total of the
requirements for each use. The required base number of parking spaces shall be counted
only once for multiple use buildings;
(3)Area measurements. All square-footage-based parking standards shall be computed on the
basis of gross floor area of all floors in a nonresidential building. Up to 15 percent of the
gross floor area may be excluded from the above calculation if the area is used for storage,
loading, unloading, or for mechanical equipment; and
(4)Vehicle fuel stations. Spaces at the pump at a vehicle fuel station may count toward the
minimum parking space requirements.
(b)Occupancy-or capacity-based standards.
(1)For the purpose of computing parking requirements based on employees, students,
residents, or occupants, calculations shall be based on the typical, or average, number of
persons working on a single shift or the typical enrollment, whichever is applicable.
(2)In hospitals, bassinets shall not be counted as beds.
(3)In the case of benches, pews, and similar seating accommodations, each 24 inches thereof
shall be counted as one seat for the purpose of determining the parking requirements. If
fixed seating is not provided, then each seven square feet of floor area shall be counted as
one seat.
(c)Unlisted uses.
(1)Upon receiving an application for a use not specifically listed in the parking schedule
below, the zoning administrator shall apply the parking standard specified for the listed use
that is deemed most similar to the proposed use in regards to use, size, and intensity of use.
(2)If the zoning administrator determines that there is no listed use similar to the proposed
use, intensity, or size, they may refer to the estimates of parking demand based on
153
CR225-464-620540.v15
Revised Figure 27:
(2) An auxiliary space cannot exceed 12 feet in width and 24 feet in length, and must be at
least ten feet from the habitable portion of a residential structure on an adjacent property;
and
(3) For access to the auxiliary space, a hard surfaced taper also is permitted, provided it does
not extend into in the boulevard provided that the taper is at least three feet back from the
curb so that the driveway approach does not exceed the curb cut width at that point (see
Option #1 of Figure 27). and has an angle of at least 22-1/2 degrees and no more than 45
degrees. If the property has setback or topographic constraints that prevent reasonable
access to a lawful auxiliary space, then the city engineer may allow the taper to extend into
the boulevard but only to the minimum extent necessary to provide reasonable access.
Subd. 10. Setbacks. Except for off-street parking lots within the TC and TC-PD districts, which
have separate requirements in paragraph (d) of this subdivision, all parking lots are subject to the setback
requirements in paragraphs (a) through (c) of this subdivision.
(a) The face of the curb shall not be within five feet of any property line and the back of the curb
shall not be within four feet of any property line.
(b) If a parking lot for a commercial, institutional, or multiple family dwelling use is adjacent to a
property used for one or two-family residential dwellings, the face of the curb for the parking
lot shall not be within ten feet of the shared property line and the back of the curb shall not be
within nine feet of the shared property line. This setback may be reduced to five feet to the
property line and four feet to the back of the curb if a permanent opaque screen fence or wall
of at least 6.5 feet in height is installed to screen the parking lot from the residential dwellings.
The screen fence may exceed typical height limitations as allowed in the Crystal city code,
subsection 520.09, subd. 1 (a) (3) (iii).
(c) All setbacks near intersections of public streets shall be determined by the city engineer.
(d) Within the TC and TC-PD districts, if a parking lot is constructed it shall be subject to the
following setback and locational requirements:
(1) Location. Off-street parking lots are prohibited in front of the building, but may be
located to the rear or side of buildings (see Figure 28);
155
CR225-464-620540.v15
Figure 29: Non-impeded access driveway.
(iv)A minimum unobstructed clearance height of 14 feet shall be maintained above areas
accessible to vehicles within nonresidential developments.
(3)To ensure proper location and configuration, a permit is required from the city manager
or designee for work on driveways. For driveway plans that involve changes to an
existing curb cut or construction of a new curb cut within the public right-of-way, a right
of way permit application shall be approved in accordance with the Crystal city code,
chapter VIII.
(4)If a driveway or driveway taper extends over or otherwise covers a water curb stop, a
traffic-rated access cover or access cover approved by the city shall be installed over the
curb stop. The access cover is subject to the following standards:
i.Be of sufficient strength and construction to withstand anticipated vehicle loads; and
ii.Provide continual access to the water curb stop without requiring removal or
demolition of the driveway or taper; and
iii. Be located and constructed in accordance to the city’s water utility standards; and
iv.The city may require the property owner to replace, repair, or modify the access cover
if it becomes damaged, inaccessible, unsafe, or otherwise unsuitable for continual use.
(b)Parking space dimensions.
(1)Required dimensions. Each parking space and aisle shall comply with the minimum
dimensions in Table 12 as illustrated in Figure 30.
Table 12: Parking Space and Aisle Dimensions
Angle of
Parking
(degrees)
One-Way
Maneuvering
Aisle Width
(Feet)
“A”
Two-Way
Maneuvering
Aisle Width
(Feet)
“A”
Parking Stall Width
(Feet)
“B”
Parking Stall Length
(Feet)
“C”
Compact
Size
Low
Turnover Full Size Compact
Size
Low
Turnover Full Size
0 o – Parallel 12 20 8 8.5 9 18 22 22
30 o – 53o 14 20 8 8.5 9 16 20 20
182
CR225-464-620540.v15
Subd. 3. Prohibited signs. The following signs are prohibited:
(a) Any sign, signal, marking or device which purports to be or is an imitation of or resembles any
official traffic control device or railroad sign or signal, or emergency vehicle signal, or which
attempts to direct the movement of traffic or which hides from view or interferes with the
effectiveness of any official traffic-control device or any railroad sign or signal;
(b) All off-premise signs;
(c) Signs painted, attached or in any other manner affixed to trees, rocks, or similar natural
surfaces, or attached to public utility poles, bridges, towers, or similar public structures;
(d) Signs placed in the public right-of-way, other than the following:
(i) Governmental signs;
(ii) Courtesy bench signs allowed with an obstruction permit as regulated by the Crystal city
code, chapter VIII;
(iii) Except for home businesses and garage and yard sales, which have separate sign
requirements in the Crystal city code sections 515.23 and 515.27, respectively, Signs signs
placed in public right-of-way that are maintained by the owner or occupant of residential
property abutting said right-of-way. Each sign is limited to 30 inches in height and six
square feet in area, and the cumulative area of all signs is limited to 0.5 square feet of sign
area per lineal foot of frontage on the right-of-way; and
(iv) Sandwich board signs are permitted in the public right-of-way but shall not interfere with
public use of the sidewalk or right-of-way. The city’s public works director has authority
to determine if a sign is interfering.
(e) A sign, including unshielded display lighting, that obstructs or distracts the vision of drivers or
pedestrians, or detracts from the visibility of any official traffic control device;
(f) A sign that contains, imitates, interferes with, obscures or causes confusion with an official
traffic sign or signal, except for private, on premise directional signs;
(g) Abandoned signs;
(h) Roof signs; and
(i) Vehicle signs.
530.05. Sign design standards.
Subd. 1. Computations. The following principles shall control the computation of sign area and
sign height:
(a) The area of a sign face, which is also the sign area of a wall sign or other sign with only one
face, shall be computed by means of the smallest square, circle, rectangle, triangle, or
combination thereof that shall encompass the extreme limits of the writing, representation,
emblem, or other display. This does not include any supporting framework, bracing, or
184
CR225-464-620540.v15
height for a specific sign type from ground level and shall be located on land in an area which is landscaped
or if such land is part of an approved parking area, it shall be surfaced or paved as required in this UDC.
Subd. 4. Illumination. External illumination for signs shall be so constructed and maintained that
the source of light meets the requirements of the Crystal city code, subsection 520.07. In addition,
illuminated signs, including electronically or electrically controlled readerboards, within 500 feet of a one
family attached or detached dwelling or a two-family dwelling shall not be illuminated between the hours
of 10 p.m. and 6 a.m.
Subd. 5. Intersections. A sign or sign structure shall comply with the visibility requirements in the
Crystal city code, chapter VIII.
530.07. Maintenance and repair.
Subd. 1. Maintenance. Every sign shall be maintained in a safe, presentable and good structural
condition at all times, including the replacement of defective parts, painting, repainting, cleaning and other
acts required for the maintenance of the sign.
Subd. 2. Repairs.
(a) Any sign located in the city which may now be or hereafter become out of order, rotten or
unsafe, and every sign which shall hereafter be erected, altered, resurfaced, reconstructed or
moved contrary to the provisions of this subsection, shall be removed or otherwise properly
secured in accordance with the terms of this subsection by the owners thereof or by the owners
of the grounds on which said sign shall stand, upon written notice by the city. No rotten or
other unsafe sign shall be repaired or rebuilt except in accordance with the provisions of this
subsection and upon a permit issued by the city.
(b) In the event of the failure of the owner or person, company or corporation having control of
any sign, or the owner of the ground on which the sign is located, to remove or repair said sign
within 60 days after the use is terminated, a written notice shall be given and the sign may be
removed by the city at the expense of the owner or manager of the sign, or the owner of the
ground upon which the sign stands.
530.09. Allowed sign types.
(a) Table 14 lists the sign types allowed within each zoning district. The symbols and headings
used in the table are defined as follows:
(1) A “P” in a cell indicates a sign type that is allowed in the zoning district with an approved
sign permit application;
(2) An “A” in a cell indicates a sign type that is allowed in the zoning district, but is exempt
from obtaining a sign permit;
(3) A cell with a “-“ indicates a sign type that is not allowed in the zoning district; and
(4) The “sign specific standards” column cross-references standards that are specific to an
individual sign type and are applicable to that sign in all districts unless otherwise stated in
the sign specific standards.
185
CR225-464-620540.v15
Table: 14: Signs allowed by zoning district
Sign Type
Zoning District
Sign Specific Standards
R-1 R-2 R-3 NC C TC I AP
Canopy,
Marquee, and
Fixed
Awnings
P P P P P P P P 530.11, subdivision 1
Electronically
or electrically
controlled
readerboard
P P P P P - P P 530.11, subdivision 2
Electric
P P P P P P P P
Freestanding
- - - - P - P P 530.11, subdivision 3
Governmental A A A A A A A A
Monument
P P P P P P P P 530.11, subdivision 4
Multiple
Tenant
- - - P P P P - 530.11, subdivision 6
Off-Premise
- - - - - - - -
Projecting
- - - P P P P P 530.11, subdivision 5
Roof
- - - - - - - -
Rotating
- - - - - - - -
Sandwich
board
- - - P P P - - 530.11, subdivision 7
Shimmering - - - - P - P P
Temporary
P P P P P P P P 530.11, subdivision 8
Small
A A A P A A A A
Wall
P P P P P P P P 530.11, subdivision 9
530.11. Sign specific standards. The following requirements for specific sign types apply in addition to
those requirements found in Table 14.
Subd. 1. Canopies, marquees and fixed awnings. Signs are allowed on canopies, marquees and
fixed awnings, which are an integral part of the structure to which they are attached. Within the residential
districts, these signs are only allowed for multiple family dwellings, or institutional or commercial uses,
186
CR225-464-620540.v15
but are allowed for all building types in the commercial and industrial districts. Canopy, marquee, and
fixed awning signs are subject to the following standards:
(a) An awning, canopy or marquee may not project into the public right-of-way nearer than 30
inches to the street curb or curb line;
(b) The bottom of awning signs shall be no less than eight feet above the sidewalk or grade at any
point;
(c) Awnings, canopy or marquees projecting into the required yards may not be enclosed except
with a transparent material permitting through vision;
(d) Awnings, canopies or marquees built over the public right-of-way must be included in a
liability insurance policy holding the city free of all responsibility; and
(e) Canopies and marquees are a part of the building structure but the area of canopies and
marquees may not be used in the computation of total wall area.
Subd. 2. Electronically or electrically controlled readerboards. Electronically or electrically
controlled readerboards are permitted provided that the sign:
(a) Displays a given copy or graphic image for a minimum of three seconds within the readerboard
frame if having lamps of a single color, or for a minimum of sixty seconds if having lamps of
more than one color;
(b) Is included in an otherwise permitted and conforming wall, free-standing or monument sign,
and the area of the readerboard may not exceed 50% of the sign face in which it is integrated,
or 50 square feet, whichever is less, and only one readerboard per premise is allowed;
(c) Displays a static message with no fade, dissolve, scrolling, blinking, flashing, spinning or
zooming action; and
(d) Does not cast light on any public street in excess of one foot candle at the lot line along said
street, or in excess of 0.4 foot candle at the lot line of any residential property.
(e) In the NC district, copy or graphic images for an electronic readerboard shall not be displayed
between the hours of 9:00 p.m. and 7:00 a.m.
Subd. 3. Freestanding or pylon signs. Freestanding or pylon signs are subject to the following
standards:
(a) Freestanding or pylon signs shall meet the requirements in Table 15; and
(b) An electronically or electrically controlled reader board is allowed as part of a freestanding or
pylon sign.
187
CR225-464-620540.v15
Table: 15: Freestanding or Pylon Signs
Sign Type Number
Allowed
Maximum
Height
Area Minimum
Street
Frontage
Setback From
Lot Line
Setback
From
Right-of-
Way
Freestanding
or pylon sign
1 [1] 25 feet 1 square foot
of sign per
linear foot of
frontage [2]
50 feet 10 feet, and 50
feet from
residential use,
park, school,
library, church
or similar land
use [3]
10 feet
Notes:
1. A property abutting more than one street may have one additional freestanding sign on one of the
additional street rights-of-way provided that such right-of-way is on an arterial or collector street and such
sign is more than 50 feet distant from any other freestanding sign on the property.
2. The area of a sign may not exceed the following square footages based on the street the sign abuts:
1. Principal arterial - 200 square feet
2. Minor arterial or major collector – 150 square feet
3. Minor collector – 100 square feet. For the purposes of this UDC, frontage roads are defined as minor
collector streets.
4. Local – 50 square feet
3. All parts of a freestanding sign (supports, structure, display, or trim) shall meet this setback requirement.
Subd. 4. Monument signs. Monument signs are subject to the following standards:
(b) In the residential districts, monuments signs are only allowed for multiple family
dwellings or institutional or commercial uses;
(c) Monument signs shall meet the requirements in Table 16; and
(d) Except in the TC district, an electronically or electrically controlled reader board is
allowed as part of a monument sign.
Table: 16: Monument Signs
Sign Type Number
Allowed
Maximum
Height
Area Setback From
Any Property
Line
Setback
From
Right-of-
Way
Monument 1 [1] 6 feet in R-1,
R-2, R-3,
NC and TC;
25 feet in C,
I and AP
Maximum 75
square feet in
R-1, R-2, R-3
and TC; same
area
requirements
as
10 feet 10 feet
189
CR225-464-620540.v15
(b) Freestanding signs. Where allowed, one freestanding sign shall be permitted for each multiple-
tenant building.
(c) Canopies and awnings. The design of canopies shall be in keeping with the overall building
design in terms of location, size, and color. No canopies with visible wall hangers shall be
permitted. Signage on canopies may be substituted for allowed building signage and shall be
limited to 25% of the canopy area.
Subd. 7. Sandwich board signs. Sandwich board signs are subject to the following standards:
(a) Signs shall not exceed six square feet in size;
(b) One sign is allowed per property. Within the TC district, and for multiple tenant commercial
buildings on one property, one sign is allowed per business; and
(c) Signs shall only be displayed during business operating hours.
Subd. 8. Temporary signs. Except for those signs specifically exempt in the Crystal city code
subsection 530.03, subdivision 2, the temporary use of banners, pennants, balloon signs, portable signs and
similar devices requires a permit. The permit is valid for seven consecutive days. Not more than six permits
for each property, or if applicable each tenant in a multiple tenant building, may be granted in a 12-month
period. The permit must be prominently displayed at the principal use in the same manner required for
building permits. Temporary signs shall not exceed 50 square feet in area and eight feet in height and shall
conform to the relevant location requirements in the Crystal city code section 530.03, subdivision 3.
Subd. 9. Wall signs.
(a) Wall signs in residential districts. In the residential districts, wall signs are allowed for multiple
family dwellings, or institutional or commercial uses, subject to the following standards:
(1) Wall signs are only permitted on walls fronting on a public street or facing other property
used for institutional, commercial or industrial purposes.
(2) No more than one sign is permitted on each wall.
(3) No wall sign shall exceed 10% of the wall area or 75 square feet in area, whichever is less.
(4) Wall signs for home business are allowed according to the requirements in the Crystal city
code, subsection 515.23.
(b) Wall signs in commercial and industrial districts. In the TC, NC, C, and I commercial and
industrial districts, wall signs are subject to the following standards:
(1) Wall signs shall meet the requirements in Table 18;
190
CR225-464-620540.v15
Table: 18: Wall Signs
Sign Type Number
Allowed
Area
Wall Maximum
of 2 wall or
projecting
signs per
wall
Up to 10% of the wall area
to which it is affixed when
combined with projecting
signs
(2) Buildings exceeding 80,000 square feet in size on lots of over 20,000 square feet are
permitted to have wall/projecting signage of up to 250 square feet; and
(3) A wall sign may be displayed on the side or rear of a building facing a yard not abutting
on a street under the following conditions:
(i) The sign is visible from a public roadway on which the building abuts;
(ii) The side or rear yard on the side of the building to be signed must meet district setback
requirements;
(iii) The sign(s) may not be larger in area than the largest sign permitted elsewhere on the
building; and
(iv) If the side or rear yard on the side of the building to be signed abuts a park property
or a residential use, any lighting of sign must be shielded in accordance with the
Crystal city code, subsection 520.07.
Subd. 10. Signs containing non-commercial speech.
(a) Substitution clause. The owner of any sign which is otherwise allowed by these sign
regulations may substitute non-commercial copy in lieu of any commercial or non-commercial
copy. This substitution of copy may be made without any additional approval or permitting.
The purpose of this provision is to prevent any inadvertent favoring of commercial speech over
non-commercial speech, or favoring of any particular non-commercial message over any other
non-commercial message. This provision prevails over any more specific provision to the
contrary.
(b) Notwithstanding any other provisions of these sign requirements, all signs of any size
containing non-commercial speech may be posted from August 1 as allowed by Minnesota
Statute section 211B.045 in for any general or special election year until ten days following the
general election and 13 weeks prior to any special election until ten days following the special
election.
(c) Signs containing non-commercial speech that are posted outside the time limits in subdivision
10(b) of this subsection shall not exceed 50 square feet in area and eight feet in height and shall
conform to the relevant locational requirements in the Crystal city code subsection 530.03,
subdivision 3.
Included four R-1
properties in UO-PD
4222 Brunswick Ave. N.
is included in UO-PD
4171 Adair Ave. N.
is included in UO-PD
Single-family
homes on
Edgewood Ave. N.
are not included in
UO-PD district
Attachment B
Attachment C
(G)Construction design requirements.
(1)Exterior building materials. Exterior building materials are classified as primary or secondary. Primary materials must comprise
at least 60% of the building facade. Secondary materials must comprise no more than 40% of the building facade.
(a)Primary materials in the B-1, B-2, B-3, B-5 and B-6 Zoning Districts. Primary exterior building materials in the B-1, B-2, B-3, B-
5 and B-6 Districts include brick, stone, stucco, glass, or other similar maintenance-free materials that are designed for durability as
proven through industry standards and approved through the site plan review process. Materials must be colored only by means of a
pigment integral to the material, not applied to the surface.
(b)Primary materials in the B-4, I-1 and I-2 Zoning Districts. Primary exterior building materials in the B-4, I-1 and I-2 Districts
include brick, stone, stucco, glass, concrete masonry units (CMU) which are textured, burnished or decorative, or other similar
maintenance-free materials designed for durability as proven through industry standards and approved through the site plan review
process. Materials must be colored only by means of a pigment integral to the material, not applied to the surface.
(c)Secondary materials in the B-1, B-2, B-3, B-5 and B-6 Zoning Districts. Secondary exterior building materials in the B-1, B-2,
B-3, B-5 and B-6 Districts include, textured, burnished or decorative integrally colored block, or synthetic stucco above eight feet.
Materials must be colored only by means of a pigment integral to the material, not applied to the surface. Other secondary exterior
building materials include wood or metal. Any metal surface must be coated or anodized with a non-reflective glare-free finish.
(d)Secondary materials in the B-4, I-1 and I-2 Zoning Districts. Secondary exterior building materials in the B-4, I-1 and I-2
Districts include synthetic stucco above eight feet, wood or metal. Any metal surface must be coated or anodized with a non-reflective
glare-free finish.
(2)In the B-1, B-2, B-3, B-4, B-5 and B-6 Districts, all exterior vertical surfaces must be treated as a front and be equally attractive
on all sides of the structure.
(3)Window coverage in B-1, B-2, B-3, B-5 and B-6 Zoning Districts, buildings containing office and retail uses must maintain at
least 40% window coverage on each first floor front that faces a street, parking lot or open space.
(4)Building facades in B-1, B-2, B-3, B-4, B-5 and B-6 Zoning Districts, all exterior building walls adjacent to a street, parking lot or
open space must not exceed 60 feet in length without visual relief of two or more of the following:
(a)The facade is divided architecturally with different materials or textures;
(b)There are horizontal offsets of at least two feet in depth;
(c)There are vertical offsets in the roof line of at least two feet; and
(d)The windows on the first floor are recessed horizontally at least one foot.
8/24/26, 8:53 AM § 153.031 SITE PLAN APPROVAL PROCEDURE AND DESIGN REQUIREMENTS IN RESIDENTIAL DISTRICTS.
https://codelibrary.amlegal.com/codes/weststpaul/latest/weststpaul_mn/0-0-0-5247#JD_153.031 1/1
West St.
PaulAttachment D
a)
b)
c)
d)
e)
f)
g)
a)
b)
544.07. - Architectural standards.
Subdivision 1.[Generally.] Architectural plans shall be prepared by an architect or other qualified person
and shall show the following:
Elevations of all sides of the building;
Type and color of exterior building materials;
Typical floor plans;
Dimensions of all structures;
The location of trash containers and of exterior electrical, heating, ventilation, and air
conditioning equipment;
Utility plans including water, sanitary sewer, and storm sewer; and
Additional plans deemed necessary by the Director.
Subd. 2.Building orientation. Buildings shall be oriented so that at least one (1) principal entrance faces
the public street. On corner lots where the intersecting streets have different classifications, the principal
entrance shall face the street with the higher classification. Building entrances shall:
Be architecturally emphasized and highly visible from the street; and
Utilize design features that protect pedestrians from the rain and sun, such as awnings,
canopies, or porticos;
See also Section 509.07, Subd. 5 (Amended Bill No. 2025-12)
Subd. 3.Exterior Materials. The exterior wall surfaces of all non-residential structures shall be
constructed of wood, brick, stone, cementitious planks (e.g., Hardiplank®), glass, architectural concrete
textured surfaces or other materials of high quality as approved by the Director.
The exterior wall surface for all residential structures shall be constructed of wood, brick, stone,
cementitious planks (e.g., Hardiplank®), glass or other materials of high quality as approved by the Director.
Finished metals shall be used only above the ground floor and shall not exceed 40 percent of any exterior
wall surface and may not have a metallic finish.
For both residential and non-residential structures, unadorned pre-stressed concrete panels, standard
concrete block and unfinished metal, except naturally weathering metals such as copper, shall not be
permitted as exterior materials for buildings. This restriction shall apply to all principal structures and to all
accessory buildings, including parking ramps, except those accessory buildings not visible from any exterior
lot line. (Amended Bill No. 2025-12)
Subd. 4.Architectural Design/Compatibility. The exterior architectural appearance of the proposed
structure shall not be so at variance with the exterior architectural appearance of existing structures within
the immediate area, or with the intended character of the applicable zoning districts, taking into
8/21/26, 1:51 PM Richfield, MN Code of Ordinances
about:blank 1/3
Richfield
a)
b)
i.
ii.
iii.
consideration building materials, size, shape and heights, so as to cause an adverse impact upon property
values in the immediate area, or the City as a whole, or adversely affect the public health, safety and general
welfare of the portion of the City in which the property is located, or the City as a whole.
Subd. 5.Window Treatment.
For both residential and non-residential structures, windows or false windows shall, at a
minimum, be used on the ground level of any wall parallel to or nearly parallel to a street. The
use of bars, chains or similar security devices that are visible from a public street or sidewalk
shall be prohibited. (Amended Bill No. 2025-12)
Window requirements for residential structures shall include:
Each building wall that faces a public street, public sidewalk or public pathway, must be
comprised of no less than 30 percent windows on the first floor and no less than 20
percent windows on each floor above the first floor.
Each building wall that faces any other direction must be comprised of no less than 15
percent windows on each floor.
False windows are prohibited.
Residential window requirements are not intended to require custom window sizes or to
increase building setbacks to comply with building code. They are intended to apply in cases
when the first floor is used for interior parking. (Amended Bill No. 2025-12)
Subd. 6.Equal Façade Treatment. All buildings shall be constructed so that each exterior wall and roof
surface is finished with materials of consistent quality as those of the front wall and front roof. This
requirement, however, shall not be applicable to walls or roof surfaces which are completely screened from
view by other buildings.
Subd. 7.Façade Treatment of Accessory Structures. All structures, including parking ramps shall be
designed to be architecturally integrated into the overall site and be made of comparable materials and
decorative elements.
Subd. 8.Façade Maintenance. All façade treatments shall be maintained so as to not be unsightly in
appearance or in a state of disrepair, nor shall harmful health or safety conditions be present for the life of
the project.
Subd. 9.Color. No residential structure may display more than ten (10) percent of any elevation surface
in bright, high intensity or pure tone primary or secondary colors. No fluorescent or neon colors shall be
used on any exterior elevation surface. City-approved murals are exempt from this limitation. (Added Bill
No. 2025-12)
8/21/26, 1:51 PM Richfield, MN Code of Ordinances
about:blank 2/3
Subd. 10.Blank Walls. Residential building elevations shall consistently incorporate elements that relate
to the human scale. No wall shall be uninterrupted for more than 25 feet in length as calculated per floor.
Interruptions may include doors and windows, projections, recessions, awnings and canopies, decorative
ornamentation or other architectural elements. This requirement may also be addressed through art
installation or living walls, subject to approval by the Director. (Added Bill No. 2025-12)
Subd. 11.Building Mass. No residential building wall shall exceed 200 feet in length. Every residential
building wall length that exceeds the height of the building shall incorporate full height offsets spaced at
intervals equal to or less than the building height. The offset shall be a minimum of one (1) foot in depth and
width per story of building height. An offset can be a projection or recess. Building walls under 36 feet in
length are exempt from this standard. (Added Bill No. 2025-12)
8/21/26, 1:51 PM Richfield, MN Code of Ordinances
about:blank 3/3
f.The city acknowledges a degree of flexibility may be necessary to adjust to unique
situations. Alternatives that provide an increase in pedestrian vibrancy and street
safety including but not limited to public art and pedestrian scale amenities may
be considered and may be approved by the Zoning Administrator, unless the
development application requires approval by city council, in which case the city
council shall approve the alternate transparency plan.
(Ord. No. 2595-20, 10-19-20; Ord. No. 2602-21, 1-4-21)
(c)Building Materials. Exterior surface materials of buildings shall be installed and maintained
in accordance with the adopted building code and the manufacturer’s specifications and
shall be subject to the regulations listed below. Products listed as “integral colored” shall
continue its surface color consistently through the depth of the product as opposed to
being colored, painted, or stained on the surface only.
(1)Classes of materials. Materials shall be divided into class I, class II and class III categories
as follows:
a.Class I. The following materials are considered class 1 materials as specified:
1.Brick
2.Marble, granite, or other natural stone
3.Integral colored cast stone (the stone is colored consistently through)
4.Textured cement stucco
5.Architectural wall cladding (Nichiha, Equitone and similar brands) Material
must be through colored and at least 5/8 inches thick.
6.Copper
7.Porcelain
8.Glass
9.Wall mounted solar energy system
10.Residential buildings containing four or fewer dwelling units may utilize the
following additional materials:
i.Wood
ii.Vinyl siding
iii.Fiber-reinforced cement board
iv.Prefinished metal
11.Residential buildings containing five or more dwelling units may utilize the
following additional materials:
i.Up to 10% of the required class 1 materials may be finished with clapboard
and/or shake-style fiber-reinforced cement board with a minimum
thickness of ¼ inch.
12.Park buildings under 3,000 square feet may utilize the following additional
materials:
i.Wood.
b.Class II. The following materials are considered class II materials as specified:
1.Exposed aggregate concrete panels
2.Burnished concrete block
3.Integral colored split face (rock face) and exposed aggregate concrete block
4.Cast-in-place concrete
5.Insulated exterior wall panels (E.I.F.S., Drivit and similar brands)
§ 36-366 Architectural Design
Supp. No. 43 (01-23) 36:V:52 St. Louis Park Zoning Code
St. Louis Park
6.Fiber-reinforced cement board siding with a minimum thickness of ¼ inch
7.Prefinished metal.
8.Integral colored concrete panels other than smooth finished.
c.Class III. The following materials are considered class III materials as specified:
1.Unpainted or surface painted concrete block (scored or unscored)
2.Unpainted or surface painted plain or ribbed concrete panels
3.Unfinished or surface painted metal
4.Smooth finished concrete panels
5.Brick, stone, or integral colored material which has been painted
(2)New construction minimum class I materials. At least 60 percent of each building face
visible from off the site must be of class I materials except as permitted by subsection
(d)(4)c. of this section. Not more than 10 percent of each building face visible from off the
site may be of class III materials. Portions of buildings not visible from off the site may be
constructed of greater percentages of class II or class III materials if the structure
otherwise conforms to all city ordinances. The mixture of building materials must be
compatible and integrated.
(3)New construction buildings in I-G and I-P districts.
a.Not on major streets and not near residential. For buildings in the I-G and I-P
districts which are not located on a principal arterial, minor arterial, major
collector, or adjacent to or across from any neighborhood zoned property, class I
materials may be reduced to a minimum of 25 percent provided that the remaining
materials are functionally and durably equal to a class I material as certified by the
architect or manufacturer.
b.On major streets or near residential. For building walls in the I-G and I-P districts
facing on a principal arterial, minor arterial or major collector, or adjacent to or
across from any neighborhood zoned property, class I materials may be reduced to
a minimum of 25 percent provided that the remaining materials are functionally
and durably equal to a class I material as certified by the architect or manufacturer
and that the architectural design and site plan are superior quality as determined
by the zoning administrator. The architecture and site plan shall meet the following
minimum criteria to be considered superior quality:
1.The exposed height of the building wall shall not exceed 15 feet.
2.The number of required plant units shall be increased by 20 percent or the size
of 20 percent of the overstory trees installed shall be increased to 3 1/2 caliper
inches.
3.A minimum of ten percent of the building facade must be windows or glass
spandrels.
(4)Existing buildings. Existing buildings may paint or stain their exterior utilizing product
specifically formulated for its intended use. All painted or stained surfaces shall be
maintained so it is free of chipping and peeling.
(5)Temporary materials. On non-residential properties, covered patios with a permanent
solid roof may enclose the wall openings with transparent non-glass materials for up to
six months per calendar year provided the permanent exterior wall materials are not
covered.
(Ord. No. 2640-22, 1-18-22; Ord. No. 2662-23, 3-20-23; Ord. No. 2690-25, 3-3-25)
Architectural Design § 36-366
Supp. No. 46 (03-25) 36:V:53 St. Louis Park Zoning Code
102-710 Generally ������������������������������������������������������������������������������������������������������������ 7-2
102-720 Roof Types �������������������������������������������������������������������������������������������������������� 7-2
102-730 Entrance Types ������������������������������������������������������������������������������������������������ 7-6
102-740 Facade Materials ��������������������������������������������������������������������������������������������� 7-8
102-750 Facade Elements ������������������������������������������������������������������������������������������� 7-14
102-760 Utility Equipment ����������������������������������������������������������������������������������������� 7-20
Article 7 BUilDiNG DeSiGN
7-1CITY OF HOPKINS MNEffective July 28, 2022
Hopkins
102-710 Generally
102-710 (a) APPLICABILITY
The regulations of this article apply to all buildings in all
zones, unless otherwise stated.
102-710 (b) INTENT
The regulations of this Article 7, along with the building type
regulations in Article 3, are intended to improve the physical
quality of buildings, improve the long-term value and
durability of buildings, enhance the pedestrian experience,
and protect the historic form and scale of the City.
(1)Durable, High Quality. Ensure the use of well-tested,
high quality, durable, weather-resistant, exterior grade
materials on the majority of finished building surfaces,
while permitting a wider range of materials for details.
High quality materials can improve how well buildings
weather, reduce material failure rate, require lower
maintenance, have a longer life cycle and sense of
permanence, and maintain longer term value.
(2)Human-Scaled Facades. Promote clearly articulated,
well-organized facades that are easy to understand,
have a clear hierarchy, and yield building proportions
and details comfortable to and in line with the scale of
people.
102-710 (c) FRANCHISE ARCHITECTURE
Franchise architecture is building design that is trademarked
or identified with a particular franchise, chain or corporation,
used in multiple locations without being specific to the
context, and is generic or standard in nature.
(1)Not Allowed. To maintain the unique character of the
downtown, franchise architectural design is not allowed
in any zone with the -D suffix.
(2)Unique Design. Franchises or national chains must
follow the building type regulations and design
standards of this article to create a unique building
compatible with the downtown.
102-720 Roof Types
102-720 (a) GENERAL REQUIREMENTS APPLICABLE
TO ALL ROOF TYPES
(1)Roof types apply to all mixed-use zones in Article 3.
(2)The major components of any roof must meet all the
requirements of one of the roof types allowed per the
building type regulations in Article 3.
(3)Roofs for bay or bow windows and dormers are not
required to meet a roof type.
(4)Terraces, green roofs, rooftop gardens, and other
outdoor facilities are allowed on any roof and are not
considered a roof type. However, any permanently
covered area is considered a story and must meet the
following:
a.Where a cover is visible from any public way or open
space, the cover must comply with a roof type.
b.Any fully enclosed structure on a roof must meet the
tower regulations.
102-720 (b) OTHER ROOF TYPES
Other cap designs not defined in this section may be
approved by the zoning administrator with the following
requirements:
(1)Special Building. The building or portion of building
receiving the roof type must warrant a separate status
from the majority of buildings in the zone, with a
correspondence between the form of the roof and the
building use, such as a dome for a planetarium, a dome
for a place of worship, or a unique, iconic roof for a
more distinctive performing arts venue.
(2)Occupied Building Space. The roof type must not
create additional occupiable floor space beyond that
permitted by the building type.
(3)Other Design. The shape of the roof must be different
from those defined in this section, 102-720, such as a
dome, spire, or vault and not a gabled roof, hipped roof,
parapet roof, or flat roof.
102-720 (c) PARAPET ROOF TYPE
A parapet is a low wall projecting above a building’s roof
along the perimeter of the building on all street facades and
other front facades. See Figure 7-A Example of a Parapet
Roof.
(1)Parapet Height. Height is measured from the top of the
upper story to the top of the parapet.
a.Minimum height is 1.5 feet with a maximum height
of 6 feet. Up to 2 additional feet of height may be
approved for screening of mechanical equipment.
7-2 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-710 Generally
b.A shadow line must be located within 2 feet of
the top of the uppermost story. See 102-16210 for
definition of shadow line.
c.A shadow line must be located at the top of the
parapet. See 102-16210 for definition of shadow line.
(2)Occupied Building Space. Occupied building space
must not be incorporated behind this roof type. See 102-
16170 for definition of occupied building space.
(3)Rooftop Appurtenances. With the exception of solar
panels and small wind, any rooftop appurtenances must
be located towards the rear or interior of the parapet
roof. Rooftop appurtenances should be located such
that the parapet blocks their view from the sidewalk
across the street or may be located within a tower per
102-720 (f). See 102-760 for additional regulations of
mechanical and utility equipment.
Figure 7-A. Example of a Parapet Roof type
Roof Roof HeightHeight
Shadow Shadow lineslines
upper floorupper floor
102-720 (d) FLAT ROOF TYPE
This roof type is a visibly flat roof with overhanging eaves.
See Figure 7-B Example of a Tower.
(1)Maximum Slope. The maximum slope is 2:12; however,
the roof must not appear to be visibly sloped from the
street or other front frontages.
(2)Eaves. Eaves are required on all street and other front
frontages.
a.Eave Depth. Eaves must have a depth of at least 14
inches. Eave depth is measured from the building
facade to the outside edge of the eave.
b.Eave Thickness. Eaves must be a minimum of 6
inches thick. Eave thickness is measured at the
outside edge of the eave, from the bottom of the
eave to the top of the eave.
(3)Interrupting Vertical Walls. Vertical walls may interrupt
the flat roof and extend above the top of the eave with
no discernible roof type.
a.No more than one-third or 30 feet, whichever is less,
of any front facade may consist of an interrupting
vertical wall.
b.Vertical walls shall extend no more than 8 feet above
the top of the eave.
(4)Occupied Building Space. Occupied building space
must not be incorporated behind this roof type, including
the flat roof and vertical wall. See 102-16170 for definition
of occupied building space.
(5)Rooftop Appurtenances. With the exception of solar
panels, rooftop appurtenances may not be located
on the flat portion of this roof type. Any rooftop
appurtenances may be located behind the interrupting
vertical wall with no visibility from the sidewalk across
the street or may be located within a tower per 102-720
(f).
Figure 7-B. Example of a Flat Roof type
RoofRoof
Eave Eave DepthDepth
Eave Eave ThicknessThickness
Vertical Vertical Wall PlaneWall Plane
upper floorupper floor
7-3CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-720 Roof Types
102-720 (e) PITCHED ROOF TYPE
This roof type is a sloped or pitched roof, where the slope
occurs on all street and other front facades. Slope is
measured with the vertical rise divided by the horizontal
span or run. See Figure 7-C Examples of a Pitched Roofs.
(1)Pitch Measure. The roof may not be sloped less than
a 4:12 (rise:run) or more than 14:12. Slopes less than 4:12
are permitted to occur on second story or higher roofs.
(2)Configurations.
a.Hipped, gabled, and a combination of hips and
gables with or without dormers are allowed. When
the ridge line runs parallel to any street or other front
frontage, one of the following must occur:
1.A gabled end or perpendicular ridge line must
occur at least every 100 feet of roof; or
2.One dormer must be provided for every 15 feet
of ridge line on any street or front frontage with
at least one dormer per frontage.
3.Occupied building space within the roof is
allowed and counts as a half or full story. See
102-16210 definition of half story and any half
story limitations per the building type regulations.
See 102-16170 for definition of occupied building
space.
b.Butterfly (or inverted gable or V-shaped roof) and
shed roofs are not allowed, except per the following:
1.The butterfly or shed roof must not exceed 8 feet
in total height, inclusive of overhang.
2.The portion of the building footprint below the
butterfly roof may not be greater than 5,000
square feet.
3.Occupied building space within the roof is
allowed and counts as a half or full story. See
102-16210 definition of half story and any half
story limitations per the building type regulations.
See 102-16170 for definition of occupied building
space.
c.Mansard roofs are not allowed. Gambrel roofs are
allowed, provided the following are met:
1.The main ridge line of the gambrel roof must be
perpendicular to the front street.
2.Gambrel roofs with the ridge parallel to a side
street must include one dormer for every 15
feet of ridge line with at least one dormer per
frontage.
Figure 7-C. Examples of Pitched Roof type
Low Pitched Roof Roof type (Hip Roof)
upper floor
Pitched Roof type (Gable Roof)
upper floor
upper floor
Parallel Pitched
Roof Roof SlopeSlope
Roof Roof HeightHeight
Roof Roof HeightHeight
Roof Roof HeightHeight
Roof Roof SlopeSlope
Roof Roof SlopeSlope
Figure 7-D. Example of a Tower
Tower WidthTower Width
Tower Tower WidthWidth
Tower Tower HeightHeight
Allowable Allowable Roof typeRoof type
7-4 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-720 Roof Types
3.The steepest portion of the roof must be no
greater than the tallest permitted height of one
upper story.
4.Occupied building space is required beneath
the gambrel roof and counts as a half or full
story, based upon the percentage of footprint
allowed for a half story within the building type
regulations. See 102-16210 definition of half story
and any half story limitations per the building
type regulations. See 102-16170 for definition of
occupied building space.
(3)Maximum Roof Height. Roofs without occupied building
space and/or dormers must have a maximum height
on front and non-front frontage facades equal to no
more than 1.5 times the upper story floor to floor height
utilized on the building.
(4)Rooftop Appurtenances. With the exception of solar
panels, antennae, and wind turbines, any rooftop
appurtenances must be recessed within the pitched
roof with no visibility on any street elevation drawing.
See 102-760 for additional regulations of mechanical
equipment.
102-720 (f) TOWERS
A tower is a vertical element that must be used with other
roof types. See Figure 7-D Example of a tower.
(1)Degree of Enclosure. A street facade tower must
be fully enclosed. Any interior building tower may be
partially or fully enclosed. A fully open structure, such as
a rooftop gazebo is not a tower.
(2)Quantity. Unless otherwise defined in the building type
regulations, the following is allowed:
a.Street Facade Towers. A maximum of 2 towers
located within 15 feet of any street facade is
permitted on any building. Street facade towers
enhance the facade design.
b.Interior Building Towers. Two additional towers
are permitted provided the towers are located a
minimum of 30 feet from any street facade. Interior
towers are typically functional, providing housing for
utilities or access to the roof.
(3)Tower Height
a.Maximum height, measured from the top of the
uppermost floor of the building to the top of the
tower shaft, not including the tower roof, is the
equivalent of the height of one upper floor of the
building to which the tower is applied.
b.A tower allows for up to one additional story of
height within the tower footprint to any building type
where permitted.
(4)Tower Footprint
a.A tower footprint may be polygonal (simple, e.g.
hexagonal or octagonal), rectalinear, or cylindrical in
plan.
b.The maximum width in any direction of the footprint
of any tower is 1/3 the width of any street or front
facade or 30 feet, whichever is less.
(5)Tower Spacing. Street facade towers, within 15 feet of
any street facade, must be spaced a minimum of 120
feet from other street facade towers. Interior building
towers must be located a minimum of 60 feet from any
other tower.
(6)Transparency. Towers that meet the minimum floor-
to-floor to height of the building type and are located
within 30 feet of a street facade shall meet the minimum
front street facade transparency requirements of an
upper story of the building type to which the tower is
applied.
(7)Horizontal Shadow lines. If the tower extends the
building up to a 5th or higher story, a shadow line is
required between the 4th and 5th stories on any tower.
Shadow lines required by the roof type used on the
tower also apply.
(8)Occupied Building Space. Towers may be occupied by
the same uses allowed in upper stories of the building
type to which it is applied. See 102-16170 for definition of
occupied building space.
(9)Rooftop Appurtenances. No rooftop appurtenances are
permitted on tower roofs. Roof appurtenances may be
housed within a tower.
(10)Tower Roof. The tower may be roofed by the parapet,
pitched, or flat roof types.
7-5CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-720 Roof Types
102-730 Entrance Types
102-730 (a) APPLICABILITY
The following entrance type regulations apply to buildings
in the mixed-use and public-institutional zones. The facade
regulations for each building type regulate which entrance
types are allowed on the building types. See Article 2 and
Article 3 for building types.
102-730 (b) STOREFRONT ENTRANCE TYPE
(1)Recessed Entrance. Where the sidewalk outside
the storefront is less than 7 feet in width, measured
perpendicular to the facade, entrances must be
recessed as follows:
a.The door must be recessed a minimum of 3 feet
and a maximum of 8 feet deep, measured from the
main building facade, and may exceed the maximum
setback regulation.
b.The maximum width of the recess is 10 feet.
(2)Transparency. A minimum amount of ground story
storefront glass is required per the building type
regulations.
a.The storefront glass must turn the corner of any
recessed entry as shown in Figure 7-E.
b.Transom windows above doors are encouraged.
Transom windows are encouraged to extend along
all storefront windows.
(3)Clear Windows. Windows must be unobstructed during
the daytime and evening hours. Displays inside the
building, viewable from outside the window, may be
included, but the area on the other side of the window
display must be occupied building space with daylight
extending into the space. See 102-10100 for window
signs.
(4)Bulkhead. Where a bulkhead is incorporated, the
maximum height is 24 inches. A bulkhead is the lower
set of panels or low wall upon which the storefront
windows rest. See Figure 7-E. The bulkhead may be
constructed of wood, metal, stained concrete, spandrel
glass, or masonry. Concrete masonry units may not be
exposed.
102-730 (c) STOOP ENTRANCE TYPE
A stoop is a small, open platform that may include a canopy
or roof cantilevered off the building and may or may not be
elevated above the sidewalk.
(1)Stoop Size. Stoops must be a minimum of 4 feet wide
and 3 feet deep.
BulkheadBulkhead
Storefront Storefront GlassGlass
Transom Transom WindowWindow
Sign Sign BandBand
Horizontal Horizontal Shadow Line per Shadow Line per building typebuilding type
Recessed EntryRecessed Entry
Windows Windows extending into extending into recessrecess
Figure 7-E. Example of a Storefront Entrance
Figure 7-F. Example of Elevated Storefront
street sidewalkstreet sidewalk StorefrontStorefrontBasementBasementEntryEntry
Platform Level SidewalkPlatform Level Sidewalk
Landscape Area or Landscape Area or Visible BasementVisible Basement
ramp down to grade ramp down to grade
7-6 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-730 Entrance Types
(2)Ramps. Where feasible, ramps should be incorporated
at the principal building entrance and designed as an
integrated part of the stoop, with rails matching any
provided on steps.
102-730 (d) PORCH ENTRANCE TYPE
A porch is a raised, roofed platform that may or may not
be enclosed on all sides and may or may not be elevated
above the sidewalk.
(1)Transparency. If a porch is enclosed, refer to the
building type for minimum transparency requirements.
(2)Porch Size. The porch shall be a minimum of 5 feet
deep and 8 feet wide.
(3)Height. Porch may be 2 stories to provide a balcony on
the second floor.
(4)Ramps. Where feasible, ramps should be incorporated
at the principal building entrance and designed as an
integrated part of the stoop, with rails matching any
provided on steps.
Visible BasementVisible Basement
Figure 7-G. Example of Stoop Entrance
Figure 7-H. Example of Porch Entrance
Ramp to Ramp to StoopStoop
Raised, Raised, Uncovered StoopUncovered Stoop
7-7CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-730 Entrance Types
102-740 Facade Materials
102-740 (a) APPLICABILITY
All facades on all buildings in any zone except N zones must
meet the regulations for facade materials in this section.
102-740 (b) MAJOR STREET FACADE MATERIALS
Major facade materials are intended to serve as the primary
surface material of street facades and other highly visible
front facades.
(1)Street and Other Front Facades. Allowed major facade
materials, listed in Table 7-1, must be applied to a
minimum of 65% of all street or other front facades, not
including window and door areas. Other front facades
include those facing civic spaces, as defined in 102-350
(e).
(2)Simplicity of Facade Materials. A single major facade
material must be used for each building facade
segment, 60-foot or larger. See Figure 7-I.
(3)Exception. For IX-S zone, street facades located more
than 100 feet from the street are exempt from the major
facade material requirements.
(4)Side and Rear Facades. When side yards between two
buildings are a total of 5 or more feet in width, major
materials must be applied along that side facade from
the front of the building a distance equal to the width of
the side yard, as measured perpendicularly between the
two side facades.
(5)Original Facade Materials. Where brick or stone is an
existing building's original facade material, the following
applies:
a.The original brick or stone may be maintained if in
good condition or repaired, or the brick or stone may
be replaced by new brick or stone.
b.A different major material may not be installed over
the original brick or stone.
102-740 (c) MINOR STREET FACADE MATERIALS
(1)Maximum Minor Materials for Street Facades. A
maximum of 35% of each street or other front facade
surface, not including window and door areas, may be
composed of minor facade materials per Table 7-2.
Other front facades include those facing civic spaces, as
defined in 102-350 (e).
(2)Accents and Details. Additional materials are allowed
for trim, accents, and details per Table 7-4, not included
in the maximum surface area.
102-740 (d) SIDE & REAR FACADE MATERIALS
(1)Rail and Trail Facades. Interior side and rear (non-
street) facades along any rail line and along any trail,
such as the Minnesota River Bluffs Trail, must be faced in
a major facade material, a minor facade material (unless
Figure 7-I. Major vs. Minor Materials
Major Facade Major Facade MaterialMaterial
Major Facade MaterialMajor Facade Material
Minor Facade Minor Facade MaterialMaterial
Minor Facade Minor Facade MaterialMaterial
Minor Facade MaterialMinor Facade Material
Accent Material Accent Material (column)(column)
Minor Facade MaterialMinor Facade Material
Building Segment (must turn corner)Building Segment (must turn corner)Building Segment Building Segment
Min. 60-ft.Min. 60-ft.Min. 60-ft.Min. 60-ft.Min. 60-ft.Min. 60-ft.
7-8 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-740 Facade Materials
otherwise noted in Table 7-3), or a material as allowed in
Table 7-3.
(2)All Other Side and Rear Facades. All interior side and
rear (non-street) facades not located on a rail or trail
line must be faced in a major facade material, a minor
facade material (unless otherwise noted in Table 7-3), or
a material as allowed in Table 7-3.
102-740 (e) PITCHED ROOF MATERIALS
Allowed pitched roof materials include dimensional asphalt
composite shingles, wood shingles and shakes, metal tiles or
standing seam, slate, ceramic tile, engineered wood or slate.
102-740 (f) APPROPRIATE GRADE OF MATERIALS
All doors, windows, and hardware must be of commercial
grade quality with the exception of those on Row and House
buildings.
102-740 (g) MATERIALS INSTALLATION
The following materials installation requirements are
intended to advance the quality of construction, durability,
and aesthetics of new buildings, specifically related to
application and detailing of facade materials.
(1)Changes in Facade Materials. Changes in facade
materials, whether major materials or minor materials,
should occur mainly at concave corners or changes in
facade planes.
(2)Materials Hierarchy. A hierarchy of materials must be
maintained on the building facade, where "heavier",
articulated unit materials (brick, concrete masonry
units, stone) are located at the base of the facade and
"lighter", constant surface materials with fewer seams
(stucco, panels) are located above those on the facade.
(3)Shadow Lines on Surfaces. Shadow lines must
delineate changes in materials with solid materials
of a thickness that is greater than 1.5 inches, such as
cast stone, masonry, or stone. For example, cast stone
elements or brick may be offset to create a shadow.
7-9CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-740 Facade Materials
Table 7-1. Allowed Major Facade Materials
BUILDING TYPES & ZONES
MAJOR FACADE MATERIAL (alphabetical)
STOREFRONT,
GENERAL BUILDINGS
COMMERCIAL HOUSE, ROW
BUILDING, TRADITIONAL
HOUSE
WORKSHOP-
WAREHOUSE
CIVIC
BUILDING
MX-D, MX-N,
RX-D, RX-N,
NX2
MX-TOD,
RX-TOD,
MX-S
IX-TOD,
IX-S MX-N, RX-N, NX1, NX2 IX-TOD, IX-S,
I-TOD ALL
AA Brick
full dimensional, economy, unit, face brick 44 44 44 44 44 44
BB Concrete Masonry Units
architectural, minimum 3” depth, “artisan
stone” look, varied sizes, (Eschelon Masonry
or approved equal), “stone” face, “hewn
stone”, rock cut
–44 44 –44 44
CC Fiber Cement Board
panels, finished lap siding or shingles – – –
44 –44
DD Glass
curtain wall – –
44 –44 44
EE Metal, Architectural
architectural panel, cladding system (steel,
titanium, zinc)
– –
44 –44 44
FF Stone
natural, units 44 44 44 44 44 44
Stucco
cement-based, 2-3 layer hard coat –44 44 –44 44
GG Vinyl & PVC Siding
minimum �040 in� thick – – –
44 – –
HH Wood or Composite Wood
painted, stained, charred, or treated lap
siding, shingles, board & batten, rainscreen
– – –
44 – –
AA
BB BB
CCAA
7-10 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-740 Facade Materials
Table 7-2. Allowed Street Facade Minor Materials
All major facade materials allowed on the building type in the zone per Table 7-1 may be used for minor facade materials, unless otherwise
listed as prohibited�
MINOR FACADE MATERIAL (alphabetical)
ALLOWED
ON BUILDING TYPES OTHER LIMITATIONS
MAXIMUM AMOUNT
ON STREET & OTHER
FRONT FACADES
Concrete Surfaces
finished, stained, painted, treated All Below ground floor only 15%
BB
Concrete Masonry Units
architectural, minimum 3” depth, “artisan stone”
look, varied sizes, (Eschelon Masonry or approved
equal), “stone” face, “hewn stone”, rock cut
All –35%
JJ
Concrete Masonry Units
minimum 3” depth, split-faced, burnished/ground
face, glazed, or honed
Workshop-Warehouse –35%
CC Fiber Cement Board
finished panels All
Major material is required
at grade up to 2 feet and
adjacent to entrances
35%
DD Glass
curtain wall
All except Traditional and
Commercial House –35%
EE
Metal Architectural
architectural panel, cladding system (steel,
titanium, zinc)
All, except buildings in MX-
D, RX-D and all Commercial
House, Traditional House
Major material is required
at grade up to 2 feet and
adjacent to entrances
35%
LL Stucco
synthetic or with elastomeric finishes All Only 3rd or higher stories 35%
Stucco
cement-based, 2-3 layer hard coat All –35%
Terracotta or Ceramic
tiles or panels All –35%
HH
Wood
painted, stained, treated, natural, or aged lap
siding, shingles, board & batten
All –35%
II
Wood, Composite
lap siding, shingles, board & batten, rainscreen
system
All –35%
EE EE
CC DD
7-11CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-740 Facade Materials
Table 7-3. Allowed Non-Street Facade Materials
All allowed major facade materials and minor facade materials may be used on 100% of non-street facade, unless otherwise indicated below
or unless listed as prohibited in Table 7-5�
MINOR FACADE MATERIAL (alphabetical)
ALLOWED
ON BUILDING TYPES
OTHER
LIMITATIONS
MAXIMUM
AMOUNT ON
NON-STREET
FACADES
MAXIMUM
AMOUNT ON
RAIL & TRAIL
FACADES
Brick
thin, veneer All –100% 100%
PP Concrete Surfaces
unfinished , untreated, unstained, unpainted
General and Workshop-
Warehouse buildings in
IX and I zones only
–100% 35%
Concrete Surfaces
finished, stained, painted, treated All –100% 35%
II
Concrete Masonry Units
minimum 3” depth, split-faced, burnished/ground
face, glazed, or honed
All except Traditional
and Commercial House,
Row
–100% 100%
KK Glass Block
clear or patterned units without color All –35%15%
LL
Metal, Aluminum Composite
aluminum composite materials (ACM) or panels
(ACP)
All except Traditional
and Commercial House
Only 3rd or higher
stories 35% 35%
Metal, Corrugated, Other
ribbed, corrugated, sheet Workshop-Warehouse –100% 100%
Stucco
synthetic or with elastomeric finishes All Only 3rd or higher
stories 35% 35%
4 | ARCHITECTURAL MASONR
Y
P
R
O
D
U
C
T
C
A
T
A
L
O
G
PHOTO
Shippensburg University Dorm
Shippensburg, PA
Colors: A-18 (not shown) & NM-173
IDEAL FOR
• Interior & exterior facades
• Adding appeal & uniform finish
• Accent band
• Natural beauty due to aggregates
JJ
KK
LL LL
FF HH
GG
II
7-12 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-740 Facade Materials
MM
OO
NN
PP
QQ RR
Table 7-4. Allowed Detail & Accent Materials
All allowed major and minor facade materials may be used for
details, trim, and accents�
MM
Concrete Details
precast stone ornamentation, lintels, sills, banding,
columns, beams
Fiber Cement Details
trim, soffits
NN Metal Details
trim, ornamentation, lintels, beams, columns
Wood and Wood Composite Details
painted/treated trim, soffits, other approved details
OO Vinyl Details
limited to soffits, window trim; minimum �04 inches thick
Table 7-5. Prohibited Materials
Fiberglass and Acrylic Panels
all
QQ
Plastic Panels
all, including high-density polyethylene and polycarbonate
panels
RR
Stucco Moldings or Synthetic Stucco Moldings
trim, sills, cornices, banding, columns, pilasters or other 3
dimensional details
Wood
Unfinished, untreated plywood siding or panels
7-13CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-740 Facade Materials
102-750 Facade Elements
102-750 (a) APPLICABILITY
The facade element regulations in this section, 102-750,
apply to all buildings in any zone except N zones.
102-750 (b) WINDOWS
Windows on all street and other front facades of all
buildings shall be constructed consistent with the following
requirements:
(1)Amount. Each building must meet the transparency
requirements per the building regulations. See Article 3.
(2)Recessed. All windows, with the exception of ground
story storefront systems and glass curtain wall systems,
shall be recessed with the glass a minimum of 2 inches
from the facade surface material or adjacent trim.
(3)Vertically Oriented. A minimum of 70% of street facade
windows must be vertically oriented. An abutting series
of individually vertically oriented windows creating a
horizontally oriented bank of windows is acceptable.
(4)Visibility Through Glass. Reflective glass and glass
block are prohibited on street and other front facades.
Windows shall meet the transmittance and reflectance
factors established in the transparency definition (see
102-1620 (m)).
(5)Operable Windows. A minimum of 70% of all street
facade upper story windows on all buildings, except the
Workshop-Warehouse, must be operable. Ground story
storefront glass and glass curtain wall systems are not
required to be operable.
(6)Expressed Lintels. For masonry construction, the
expression of lintels must be included above all
windows and doors by a change in brick coursing or
by a separate detail or element. See Figure 7-J for
illustrations of expressed lintels.
(7)Glass Overhead Doors. Glass overhead doors utilized
for patio access, open air dining, or display and not
utilized for vehicular access, may be used for storefronts
or other window requirements on any building type,
provided all other regulations are met, and health
department licensing is obtained as required.
102-750 (c) AWNINGS & CANOPIES
Removable awnings and canopies attached to buildings
shall be constructed consistent with the requirements of this
section. See Figure 7-K for examples of awnings.
(1)Material. All awnings and canopies shall be canvas or
metal. Plastic awnings are prohibited.
Figure 7-J. Vertically Oriented Windows with Expressed Lintels
Metal Awning
Canvas Awning
Figure 7-K. Examples of Awnings
7-14 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-750 Facade Elements
(2)Lighting. Backlighting is allowed only on metal awnings.
(3)Structures. Frames must be metal and wall mounted.
Support poles from the ground are prohibited except
where the awning is over 8 feet in depth and utilized for
outdoor eating areas or entrances.
(4)Canopies & Light Shelves. Permanent canopies,
projections, or overhangs used as architectural features,
light shelves, or shading devices are allowed and not
intended to be regulated by this subsection 102-750 (c).
(5)Clearance. All portions of any awning or canopy shall
provide at least 8 feet of clearance over any walkway
and 15 feet of clearance over vehicular areas.
(6)Signs. Refer to Article 10 for signs on awnings and
canopies.
102-750 (d) BALCONIES
Balconies on street facades, facades of courtyard open to
the street or civic space, and facades on civic space shall
be consistent with the requirements of this subsection. See
Figure 7-L for examples of balconies.
(1)Definition. For the purpose of this subsection, balconies
shall include any roofed or unroofed platform that
projects from the wall of a building above grade and
is enclosed only by a parapet or railing. This definition
does not include false balconies, juliet balconies, or
balconettes.
(2)Balconettes. Sometimes referred to as juliet balconies,
balconettes are false balconies consisting of a rail
and door, either without an outdoor platform or with
an outdoor platform less than 18 inches in depth.
Balconettes are allowed and do not count towards
the maximum permitted amount of balcony on a street
facade.
(3)Size. Balconies must be a minimum of 4 feet deep and
5 feet wide.
(4)Facade Coverage. A maximum of 35 percent of street
facades, calculated separately for each facade, may be
covered by balconies. The balcony area is calculated by
drawing a rectangle on the facade elevation around the
following: the platform or floor of the balcony; any rails,
walls, columns or indentations; and any ceiling, roof, or
upper balcony.
(5)Integrated Design. Balconies are intended to be
integrated with the design of the facade, avoiding
tacking the balconies onto the facade after the elevation
has been designed.
Balconies: Covers More
than 35 Percent of Facade
Balconies: Extending Off
Facade
Balconies Appropriately Attached to or Incorporated into
Facade.
NOT ALLOWED
Figure 7-L. Examples of Balconies
NOT ALLOWED
7-15CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-750 Facade Elements
a. A minimum of 50 percent of the perimeter of each
balcony must abut an exterior wall of the building,
partially enclosing the balcony.
b. The balcony support structure must be integrated
with the building facade; separate columns or posts
supporting any balcony from the ground are not
allowed.
(6) Platform. The balcony platform must be at least 3
inches thick and any underside of a balcony that is
visible from any street or public way shall be finished.
(7) Maximum Setback. When the balcony is located within
the minimum and maximum setback area, the portion of
the facade behind the balcony is exempt from meeting
the maximum setback requirement.
102-750 (e) SHUTTERS
When shutters, whether functional or not, are utilized on a
street or other front facade of any building type except a
House building type, the shutters shall meet the following
requirements. See Figure 7-N.
(1) Size. All shutters must be sized for the windows, so that,
if the shutters were to be closed, they would not be too
small for complete coverage of the window.
(2) Materials. Shutters must be wood, metal, or fiber
cement. Other synthetic and engineered woods may be
approved provided that the applicant submits a sample
and examples of high quality, local installations of the
material.
102-750 (f) SECURITY GRILLS & BARS
(1) Exterior bars and security grills are prohibited on any
street facade opening.
(2) Security grills must be fully retractable and completely
located within the interior of the building. When
retracted, the grills must not be visible from the exterior
of the building.
102-750 (g) PRINCIPAL ENTRYWAY
See Figure 7-M for examples of defined principal entryways.
Principal entrances to all buildings or units, except
storefronts, must be clearly delineated through one or more
of the following design features:
(1) Roof or Canopy. The entryway is covered by a roof or
canopy differentiating it from the overall building roof
type.
(2) Porch. The entryway is through a porch.
(3) Sidelights and Transom. Sidelights or transom windows
are included around the entryway.Figure 7-M. Examples of Defined Principal Entryways
Inappropriately Scaled Shutters.NOT PERMITTED
Figure 7-N. Examples of Shutters
7-16 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-750 Facade Elements
(4) Extended Articulation. The entryway is included in a
separate bay of the building that extends up at least 2
stories.
102-750 (h) ARCADE DESIGN
The following requirements apply to arcades. An arcade is a
covered pedestrian walkway within the recess of a ground
story. See Figure 7-O.
(1) Depth. An open-air public walkway may be recessed
from the principal facade of the building a minimum of 8
feet and a maximum of 16 feet.
(2) Height. The height of the interior space of the arcade,
measured floor to ceiling, must not exceed 16 feet.
(3) Maximum Setback. When the arcade is utilized, the
outside face of the arcade shall be considered the
front facade, located within the required minimum and
maximum setback area.
(4) Column Spacing. Columns must be spaced between 10
feet and 12 feet on center.
(5) Column Width. Columns must be a minimum of 1.5 feet
6 inches and a maximum 2 foot 6 inches in width.
(6) Arcade Openings. Openings must not be flush with
interior arcade ceiling and may be arched or straight.
(7) Horizontal Facade Division. A horizontal shadow line
shall define the ground story facade from the upper
stories.
(8) Visible Basement. A visible basement is not allowed.
102-750 (i) GROUND STORY AT SLOPING FACADES
Grade transitions on any building along a significantly slope
sidewalk or street should be designed to minimize blank
walls and maximize pedestrian-scale frontages between
waist and eye level. See Figure 7-P for examples of positive
facades along slopes.
(1) Storefronts. The following regulations apply to
storefront facades along sloping streets:
a. The interior floor level must step to match the
exterior grade within 3 feet.
b. Knee wall and retaining walls must not exceed 30
inches in height except a maximum 9-foot section of
length may be up to 48 inches in height.
c. If grade change is more than 9 feet along a single
block face, the following applies:
1. Entrance requirements may be increased to one
entrance per 90 feet of building frontage.
Figure 7-O. Example of Arcade.
sidewalksidewalk
Arcade OpeningArcade Opening
Recessed or Recessed or Interior FaceInterior Face
Column Column WidthWidth
Shadow lineShadow line
BaseBase
Figure 7-P. Examples of Ground Story along Slopes.
7-17CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-750 Facade Elements
2. Entrances adjacent to the street must be within 3
feet of the elevation of the adjacent sidewalk.
(2) Non-Storefronts. The following regulations apply to all
non-storefront facades along sloping streets:
a. Grade transitions at the building along the sidewalk
shall be designed to minimize blank walls. Multiple
front entrances along the street should activate each
segment of building section at each grade.
b. The interior floor level must step to match the
changes in exterior grade within a 3-foot range.
c. Changes can be accommodated by terraced
planters and retaining walls at the lowest heights
practicable. Retaining walls shall not exceed 30
inches in height except along a maximum 8-foot
section of frontage.
d. When the elevation of the first floor is more than
3 feet above grade, the elevation is considered a
visible basement and windows must be provided
into the basement or lower floor elevation.
102-750 (j) BUILDING VARIETY
See Figure 7-Q for examples of building facade variety with
intent of providing interest and variety along street and open
space frontages.
(1) MX Zones. Buildings must treat that frontage in
segments of 50 feet or less with the building variety
standards in 102-750 (j)(3), below.
(2) RX, IX, and NX Zones. For buildings 90 feet in length
or greater, as measured along any street or front facade,
must treat that frontage in segments of 50 feet or less
with the building variety standards in 102-750 (j)(3),
below.
(3) Standards. Each facade segment must vary by at least 2
of the following:
a. The type of dominant facade material or by color,
scale, or orientation of that material;
b. The proportion of recesses and projections within
the minimum and maximum setback area;
c. The location of the entrance and window placement,
unless storefronts are utilized;
d. Roof type, plane, or material, unless otherwise stated
in the building requirements;
e. Building height.
102-750 (k) ARTICULATION OF STORIES
Stories must be articulated on street and other front facades.
Figure 7-Q. Examples of Building Articulation
Figure 7-R. Example of a Terminated Vista.
7-18 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-750 Facade Elements
(1) Fenestration. Fenestration or window placement on
street facades must be organized by stories per the
building type facade transparency regulations.
(2) Shadow Lines. Horizontal shadow lines and lintels
over openings may be used to delineate stories with
minimum shadow lines required per building type.
(3) Mezzanines. Mezzanines that fall within the range
of floor to floor heights of the building type shall
be articulated on the facade and require separate
calculation for transparency per 102-1620 (m) (7) Tall
Stories.
(4) Taller Spaces. Spaces exceeding the allowable floor to
floor heights of the building type shall be articulated as
multiple stories on the street facade.
102-750 (l) VISTAS
Views down streets must be considered when locating open
space, parking, and buildings on sites and designing building
facades. Figure 7-R.
(1) Rears of Buildings. Rears of buildings must not be
visible at the termination of a street vista.
(2) Parking. Parking structures and surface parking lots are
not permitted at the termination of a street vista.
(3) Building Design. When a street terminates at a parcel,
the facade of a building, whether facing a front street
or not, must terminate the view and the building must
incorporate one of the following treatments to terminate
the view: a tower, a bay, or a courtyard. That portion of
the facade shall be treated as a front facade.
102-750 (m) GARAGE DOORS
The following requirements apply to garage doors included
on any street facade.
(1) Location. Allowed locations for garage doors on street
and non-street facades are regulated by the building
type regulations.
(2) Recessed from Facades. Garage doors located on
street facades must be recessed a minimum of 5 feet
from the dominant facade of the principal building facing
the same street.
(3) Design. Garage doors facing a street or visible from a
street must meet the following:
a. The doors must be clad with materials consistent
with the design of the building.
b. Upgraded architectural doors or carriage-style doors
are required on all Row buildings.
102-750 (n) PARKING STRUCTURE FACADES
Parking structure facades visible from any street or abutting
any pedestrianway or open space shall meet the following
standards. See Figure 7-R for one illustration of a parking
structure facade.
(1) Materials. Major and minor material requirements, per
102-740, above, shall be met on all street and other
front facades. An additional permitted minor material is
stained, finished concrete.
(2) Ramps and Slopes. Ramps and slopes shall not be
located on any front or street facades.
(3) Vertical Divisions. Vertical divisions extending the full
height of the structure are required every 30 feet to
deemphasize the horizontal decks. Divisions shall be a
minimum of 2 feet in width with a minimum projection of
2 inches.
(4) Blank Wall Limitations. No rectangular area greater
than 30 percent of any story’s facade, as measured from
Entry Tower
Cap
Vehicular
Entrance
Vertical
Divisions
Blank Wall
Limitations
and No
Ramps or
Slopes
Figure 7-S. One Example of a Parking Structure
7-19CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-750 Facade Elements
floor to floor, and no horizontal segment of a story’s
facade greater than 15 feet in width may be solid wall
without an opening.
(5) Entry Tower. A pedestrian entrance directly into the
parking structure from the street is required to be
separate from the vehicular entrance and directly
accessed from the sidewalk. The pedestrian entrance
must meet the principal entryway regulations in 102-750
(g). Stairwells must be located inside a tower per 102-
720 (f) with windows at a transparency rate of 65%.
(6) Cap. The top story of the parking structure shall include
a parapet or other roof type along the public way
facades. Refer to roof types defined in 102-720.
(7) Vehicular Entrances. Driveways shall be no wider than
22 feet and the entrance and exit should be split by a
median. Access shall be located on a non-front street,
unless the lot does not abut a non-front street. No
more than 2 access points shall be located on any one
street, totaling no more than 24 feet of drives crossing
sidewalk.
102-760 Utility Equipment
Mechanical and utility equipment and appurtenances are
necessary for any building design, but can have a negative
visual impact and detract from the quality of the design of
a building. The purpose of the regulations of this section,
102-760, is to ensure that the visual impact of mechanical
equipment and appurtenances is minimized.
102-760 (a) "MECHANICAL EQUIPMENT" DEFINED
When the following regulations refer to "mechanical
equipment", any mechanical equipment or utility
appurtenance, such as but not limited to HVAC systems,
boilers, condensers, transformers, vents, meters, ducts, are
being referenced, except the following:
(1) Solar and wind energy systems are allowed, subject to
102-6140 in accessory structure regulations.
(2) Rainwater cisterns are allowed.
102-760 (b) MECHANICAL EQUIPMENT IN BUILDING
Mechanical equipment shall be located within the
building, unless the applicant demonstrates that locating
the equipment within the building would conflict with the
equipment’s function.
102-760 (c) ROOFTOP MECHANICAL EQUIPMENT
Any rooftop mechanical equipment, such as but not limited
to vents, ducts, condensers, and ventilators,and not including
solar panels or wind turbines, shall be located consistent
with one of the following methods:
(1) Incorporate equipment into the roof design consistent
with the applicable standards of roof types in 102-720.
(2) Set the equipment back a minimum of 10 feet from any
street or public way facade.
(3) To the extent practicable, all rooftop mechanical shall
be painted to blend with the structural roof and limit its
visibility.
102-760 (d) MECHANICAL EQUIPMENT ON STREET
FACADES
Mechanical equipment and utility appurtenances shall
not be located on a street facade unless the applicant
demonstrates that locating the equipment in a different
location would conflict with the equipment’s function. Any
equipment or appurtenance approved on a facade shall be
located consistent with the following standards:
(1) Street Facade. The mechanical equipment may
be located on a street facade only if the following
requirements are met:
a. The equipment is located on a surface perpendicular
to the adjacent street and not parallel to the adjacent
7-20 Development CodeCITY OF HOPKINS MN
Article 7 Building Design
102-760 Utility Equipment
street, unless there is no other option, provided all
other requirements of this subsection, 102-760 (d),
are met.
b. The equipment extends from the facade surface no
more than 3 inches; and
c. The equipment is screened from the sidewalk by
landscape, railings, other facade walls, or other
designs.
(2) Air Vents or Grills. Air vents and grills may be
successfully incorporated into storefront window
systems, provided the transparency requirements are
met by the actual windows in the system.
(3) Alignment. Multiple pieces of mechanical equipment
must be organized on the facade in a regular pattern
and aligned. Compliance with this standard must be
illustrated on the drawing elevations submitted as part of
the application.
(4) Material Coordination. To the extent practicable,
facade-mounted mechanical appurtenances shall
be located on a material that limits their visibility. For
example, dark colored vents will be more visible on light
colored fiber cement panels than a textured, darker
surface such as brick.
102-760 (e) MECHANICAL EQUIPMENT ON OTHER
HORIZONTAL SURFACES
Mechanical equipment, such as electrical transformers and
air conditioners, located on the ground, decks, or horizontal
surfaces other than the roof shall be located consistent with
the following standards:
(1) No Encroachment. Mechanical equipment shall not
extend into any right-of-way or easement, unless
otherwise approved by the City.
(2) Allowed Yard Location. See 102-16270 for definition of
yards.
a. Front Street Yard. Mechanical equipment and
appurtenances shall not be located in the front street
yard.
b. Non-Front Street Yard. Mechanical equipment may
be approved in the non-front street yard, provided
the equipment is screened from the street per the
following regulations.
c. Rear and Side Yard. Mechanical equipment may be
located in any rear or side yard.
(3) Screening from streets, open spaces, or civic spaces.
All equipment must be screened from view from any
streets, open space, or civic space per the following:
a. Walls for screening must be consistent with the
building design, colors, and materials, faced with an
allowed major facade material.
b. Where landscaping only is employed, the following
must be met:
1. Where landscaping only is employed, the utility
must be located in a larger landscape area and
the landscape screen must be designed as part
of the large planting bed design.
2. A single row of evergreen shrubs shall fully
screen the equipment within 1 year of installation.
3. The zoning administrator may require additional
landscape materials.
(4) Street Frontage or Front Yard Location. Equipment
located in a street yard or other front yard may
approved only if all of the following are met:
a. The applicant demonstrates that the equipment
cannot be located in a rear yard, street side yard, or
in a side yard.
b. Equipment may be located in a front street yard only
if the applicant demonstrates that the equipment
cannot be located in a non-front street yard.
c. No other utility cabinets, boxes, or other
appurtenances are within 200 feet along the
same side of the street as the proposed utility
appurtenance.
d. The appurtenance is located a minimum of 35
feet from a street intersection, measured from the
intersection of the curb line, and does not impact the
sight vision clearance at intersections.
e. The appurtenance is fully screened in a manner
that is consistent with the building design, colors,
and materials and of a height that is the minimum
to adequately screen the appurtenance and that
does not prevent the facade from fulfilling any
transparency requirements. See Figure 5.03(8) for
examples of poorly located, unscreened equipment
on front streets.
7-21CITY OF HOPKINS MNEffective July 28, 2022
Article 7 Building Design
102-760 Utility Equipment
Figure 7-T. Utility Appurtenances located on Facades
Figure 7-U. Rooftop Utilities Screened from the Public Way by a Parapet
Figure 7-V. Examples of Poorly Located Utility Appurtenances on Primary Streets: NOT PERMITTED
Utility vents Utility vents aligned and aligned and colored to colored to match facade match facade surfacesurface
Hotel room Hotel room vents organized vents organized and integrated and integrated into the facade into the facade designdesign
Example of Example of poorly located poorly located vents on vents on contrasting contrasting materialmaterial
Example of vents Example of vents located as part of located as part of storefront window storefront window systemsystem
Utility vents Utility vents colored to colored to match facade match facade surfacesurface
7-22 Development CodeCITY OF HOPKINS MN
Article 7 Building Design